Installation

10. Properly secure strain relief (see previous section)

Note:
DO NOT plug in range at this time.

Three Wire Range Cord Connection The Four Wire Connection (above) is preferred, but where local codes and ordi­

nances permit grounding through neutral and where conversion to four wire is
impractical, the unit may be connected to the power supply via a three wire con­
nection.

1. Disconnect electrical power at breaker box.

2. Remove the terminal block cover to expose the terminal block.

Figure 16: Terminal Block

3. Remove top nut, star washer, and round washer from each post.

Note:
DO NOT remove last round washer, last nut or internal wiring leads.

4. Attach white wire, round washer, star washer and nut IN THIS ORDER on top

of ground strap on center post.

5. Attach red wire, round washer, star washer and nut IN THIS ORDER to left

post.

6. Attach black wire, round washer, star washer and nut IN THIS ORDER to right

post.

Figure 17: Three Wire Connection