beautypg.com

Leak testing valves, hose and regulator, Danger, Iturn – Kenmore 415.165059 User Manual

Page 6: Leak

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

e.Turn the coupling nut clockwise and tighten to a full stop. The

regulator will seal on the back-check feature in the LP tank

valve, resulting in some resistance.

An additional one-half to

three-quarters turn is required to complete the
connection. Tighten by hand only - do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and

repeat steps 5 and 6. If you are still unable to complete the

connection,

do not use this regulator!

t

DANGER

t

Do not insert

any

tool or foreign object into the valve

outlet or safety relief valve. You may damage the valve

and cause a leak. Leaking propane may result in

explosion, fire, severe personal injury, or death.

Outdoor gas appliance is not intended to be installed

in or on a boat.

Outdoor gas appliance is not intended to be installed

in or on an RV.

Never attempt to attach this grill to the self-contained

LP gas system of a camper trailer or motor home.

Do not use grill until leak-tested.

If a leak is detected at any time, STOP and call the fire

department.

If you cannot stop a gas leak, immediately close

LPcylinder valve and call LP gas supplier or your fire

department!

Leak

Testing Valves, Hose and Regulator

ITurn

all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP tank.

S.Completely open LP tank valve by turning OPD hand wheel

counterclockwise. If you hear a rushing sound, turn gas off

immediately. There is a major leak at the connection.

Correct

before proceeding

by calling Sears for replacement parts at

1-800-4-MY-HOME!

4.Brush soapy solution onto areas where bubbles are shown in

picture below:

. Never remove threaded

orifice

at

end of valve.

5.lf “growing”

bubbles appear, there is a leak. Close LP tank

valve immediately and retighten connections.

If leaks cannot

be stopped do not try to repair.

Call Sears for replacement

parts at

1-800-4-MY-HOME®

6.Always close LP tank valve after performing leak test by

turning hand wheel clockwise.

6

464722309