AGITATOR SERVICING

WARNING

Electrical Shock Or Personal Injury
Hazard

Disconnect electrical supply before
servicing or cleaning the unit.
Failure to do so could result in elec­
trical shock or personal injury from

cleaner suddenly starling.

TO CHECK AGITATOR
ASSEMBLY

When brushes
are worn to the

level of the base

support bars,

replace the
agitator
assembly.

TO REPLACE AGITATOR

ASSEMBLY

w

I

m

IWI LJr b» 1

1. Remove Power-Mate® cover, agitator
cover, belt and agitator assembly. See
To Remove Beif in BELT CHANGING
AND AGITATOR CLEANING.

2. Remove end caps, washers, screws,
end brush, and brush sprocket pieces
from ends of old agitator assembly

3. Reassemble agitator assembly. To line
up screw holes in dowel, sprocket and
end brush, be sure ail of the brush

sprocket pieces align properly. See
AGITATOR ASSEMBLY.

4. Reinstall bell, agitator assembly,
agitator cover and Power-Mate® cover.
See To Replace Beit" in BELT
CHANGING AND AGITATOR CLEANING.

.r.

•¡ir

AGITATOR ASSEMBLY

End

Brush

End

19