beautypg.com

Register map detail, Stk17ta8 – Cypress AutoStore STK17TA8 User Manual

Page 18

background image

STK17TA8

Document #: 001-52039 Rev. **

Page 18 of 23

Register Map Detail

0x1FFFF

Real Time Clock – Years

D7

D6

D5

D4

D3

D2

D1

D0

10s Years

Years

Contains the lower two BCD digits of the year. Lower nibble contains the value for years; upper nibble contains

the value for 10s of years. Each nibble operates from 0 to 9. The range for the register is 0-99.

0x1FFFE

Real Time Clock – Months

D7

D6

D5

D4

D3

D2

D1

D0

0

0

0

10s Month

Months

Contains the BCD digits of the month. Lower nibble contains the lower digit and operates from 0 to 9; upper nibble

(one bit) contains the upper digit and operates from 0 to 1. The range for the register is 1-12.

0x1FFFD

Real Time Clock – Date

D7

D6

D5

D4

D3

D2

D1

D0

0

0

10s Day of month

Day of month

Contains the BCD digits for the date of the month. Lower nibble contains the lower digit and operates from 0 to 9;

upper nibble contains the upper digit and operates from 0 to 3. The range for the register is 1-31. Leap years are

automatically adjusted for.

0x1FFFC

Real Time Clock – Day

D7

D6

D5

D4

D3

D2

D1

D0

0

0

0

0

0

Day of week

Lower nibble contains a value that correlates to day of the week. Day of the week is a ring counter that counts from

1 to 7 then returns to 1. The user must assign meaning to the day value, as the day is not integrated with the date.

0x1FFFB

Real Time Clock – Hours

D7

D6

D5

D4

D3

D2

D1

D0

0

0

10s Hours

Hours

Contains the BCD value of hours in 24 hour format. Lower nibble contains the lower digit and operates from 0 to

9; upper nibble (two bits) contains the upper digit and operates from 0 to 2. The range for the register is 0-23.

0x1FFFA

Real Time Clock – Minutes

D7

D6

D5

D4

D3

D2

D1

D0

0

10s Minutes

Minutes

Contains the BCD value of minutes. Lower nibble contains the lower digit and operates from 0 to 9; upper nibble

contains the upper minutes digit and operates from 0 to 5. The range for the register is 0-59.

0x1FFF9

Real Time Clock – Seconds

D7

D6

D5

D4

D3

D2

D1

D0

0

10s Seconds

Seconds

Contains the BCD value of seconds. Lower nibble contains the lower digit and operates from 0 to 9; upper nibble

contains the upper digit and operates from 0 to 5. The range for the register is 0-59.

0x1FFF8

Calibration

D7

D6

D5

D4

D3

D2

D1

D0

OSCEN

0

Calibration

Sign

Calibration

OSCEN

Oscillator Enable. When set to 1, the oscillator is disabled. When set to 0, the oscillator is enabled. Disabling the

oscillator saves battery/capacitor power during storage.

Calibration

Sign

Determines if the calibration adjustment is applied as an addition (1) to or as a subtraction (0) from the time-base.

Calibration

These five bits control the calibration of the clock.

[+] Feedback