Installation Instructions
Pre-Test Checklist
Remove all protective film, if present, and
any stickers.
Check to be sure that all wiring is secure and
not pinched or in contact with moving parts.
NOTE TO ELECTRICIAN: You must unplug
the green wire (near where the long flexible
conduit exits the unit) when conducting
high-potential testing. Please replug prior
to operation.
Check that the bottom trim is installed prop
erly (see page 12).
Check to be sure the mounting screws are
installed and flush with the side trim (see
page 11).
Operation Checklist
Remove all items from the inside
oftheoven.
SQ
Check that conduit is securely connected to
thejunction box.
Turn on the power to the oven. (Refer to your
Owner's Manual.) Verify that the bake and
broil units, and all cooking functions operate
properly.
Check that the circuit breaker is not tripped
nor the house fuse blown.
See your Owner's Manual for
troubleshooting list.
If "bAd" "LInE" appears in the display when
the power is turned on, the house wiring
connections are incorrect.
©
©
©
©-ft.©
NOTE TO ELECTRICIAN: The power leads
supplied with this appliance are UL
recognized for connections to larger gauge
household wiring. The insulation ofthese
leads is rated attemperatures much higher
than the temperature rating of household
wiring. The current carrying capacity ofa
conductor
is governed by the wire gauge and also
the temperature rating ofthe insulation
aroundthewire.
NOTE: ALUMINUMWIRING
A.
WARNING
:IMPROPER
CONNECTION OFALUMINUM HOUSE
WIRING TO THE COPPER LEADS CAN
RESULT IN AN ELECTRICAL HAZARD OR
FIRE.
B. Splice copper wires to aluminum wiring
using special connectors designed
and UL approved forjoining copper to
aluminum,
and follow the manufacturer's
recommended connector procedure
closely.
NOTE: Wire used, location and
enclosure ofsplices, etc., must conform
to good wiring practice and local codes.
14