Installation Instructions
B3
New Construction and
Four-Conductor Branch
Circuit Connection
• When installing in new construction, or
• When installing in a mobile home, or
• When installing in a recreational vehicle, or
• When local codes do not permit grounding through
neutral:
a. Cut the neutral (white) lead from the crimp.
Re-strip the neutral (white) lead to expose the
proper length of conductor.
Ground
Wire
b. Attach the appliance grounding lead (green or
bare copper) in accordance with local codes. If the
residence grounding conductor is aluminum, see
WARNING on page 9.
c. Connect the oven neutral (white) lead to
the branch circuit neutral (white or gray) in
accordance with local codes, using a wire nut.
d. Connectthe oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts. If the residence red, black or white leads
are aluminum conductors, see WARNING on page
9.
e. Install Junction Box Cover.
B4
Three-Conductor Branch
Circuit Connection
When connecting to a three-conductor branch circuit,
if local codes permit:
a. Connect the bare oven ground conductor with the
crimped neutral (white) lead to the branch circuit
neutral (white or gray in color), using a wire nut.
b. Connectthe oven red lead to the branch circuit red
lead in accordance with local codes, using a wire
nut.
c. Connect the oven black lead to the branch circuit
black lead in accordance with local codes, using a
wire nut. If the residence red, black or white leads
are aluminum conductors, see WARNING on page
9.
d. Install Junction Box Cover.