3000 12_warranty, Limited warranty, Year – Braeburn 3200 User Manual
Page 7: Premier series, Non-programmable thermostats, Wiring diagrams, Store this manual for future reference
![background image](/manuals/661722/7/background.png)
R
O
B
C
Y1
Y2
E/W1
W2
G
L
1st Stage
Compressor
Control
2nd Stage
Heat
Control
Reversing
Valve (Active
in Heating-
See NOTE 4)
2nd Stage
Compressor
Control
(if equipped)
Emergency
Heat Control
(if equipped)
Reversing
Valve (Active
in Cooling-
(See NOTE 4)
System
Monitor
(if equipped)
See
NOTE 2
24 VAC
Neutral
120 VAC
Hot
Transformer Common
(See NOTE 1)
MODEL 3200: Heat Pump Systems
NOTES:
1. Transformer Common connection not required for battery-
only operation of thermostat. 2. User installed Jumper is required to use Auxiliary
heat for both second stage and emergency heat on units without separate
emergency heat and auxiliary heat terminals. DO NOT install jumper if both
terminals are present. 3. Eliminate connection to Y2 for units with single stage
cooling. 4. For units requiring reversing valve to be energized during heating,
connect reversing valve to B terminal. For units requiring reversing valve to be
energized during cooling, connect reversing valve to O terminal.
Wiring Diagrams
9
cont.
12
Fan Control
MODEL 3200: Conventional Systems
R
O
B
C
Y2
E/W1 W2
G
Y1
2nd Stage
Heat Control
1st Stage
Heat Control
Fan Control
Transformer Common (See NOTE 1)
24 VAC
Neutral
Hot
120 VAC
L
1st Stage
Compressor Control
2nd Stage
Compressor
Control
(See NOTE 2)
NOTES:
1. Transformer Common connection not required for
battery-only operation of thermostat. 2. Eliminate connection to Y2 for
units with single stage cooling.
©2011 Braeburn Systems LLC • U.S. Patents D524,663; D536,271; 7,438,469 • All Rights Reserved.
Made in China • 3000-100-010
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)
Premier Series
Non-Programmable Thermostats
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are
due to faulty material or workmanship for a period of five years after the original date of
purchase by a professional service technician. This warranty and our liability does not apply to
batteries, nor does it include damage to merchandise or the thermostat resulting from
accident, alteration, neglect, misuse, improper installation or any other failure to follow
Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat
under warranty provided it is returned postage prepaid to our warranty facility in a padded
carton within the warranty period, with proof of the original date of purchase and a brief
description of the malfunction. This limited warranty does not include the cost of removal or
re-installation.
WARRANTY FACILITY: Braeburn Systems LLC
Attn: Warranty Department
2215 Cornell Avenue
Montgomery, IL 60538
Store this manual for future reference.
LIMITED WARRANTY
5
YEAR
WARRANTY
LIMITED
This warranty gives you specific legal rights and you may also have other rights that vary from
state to state or province to province. Answers to any questions regarding our limited warranty
may be obtained by writing our corporate offices.