5100_14_bck.pdf, Store this booklet for future reference, Troubleshooting – Braeburn 5100 User Manual

Page 8: Wiring diagram, Symptom potential solution, Wiring diagram for 2 stage heat, 2 stage cool

background image

14

TROUBLESHOOTING

6

cont.

SYMPTOM

POTENTIAL SOLUTION

Fan continues to run all

the time whether the

system is on or off.

Check that the fan control switch is in the

AUTO position. This

will allow the fan to run only when the heating or cooling system

is turned on and running.
Check thermostat wiring to make sure that the fan control

wiring is connected to the correct terminals on the wiring

terminal block. See Installation and Wiring Diagram sections of

this manual.

Fan continues to run in

cooling mode when the

system has turned off.

The Residual Cooling Fan Control Feature can allow up to a 90

second fan delay after cooling system shutdown for energy

efficiency gains. The default setting is 60 seconds. This can be

changed to disable the feature or shorten the time period if

desired. See Setting Residual Cooling Fan Feature section of

this manual.

Fan switch is in recirculate

®

mode.

The thermostat does

not allow me to program

each day separately.

Change from Weekday-Weekend to 7 Day Mode

(see section 4.4).

System turns on

prior to the end of a

setback period.

Thermostat is in Adaptive Recovery Mode – see section 5.6.

WIRING DIAGRAM

7

NOTE:

Eliminate connection to Y2 for units with single stage cooling.

R

Y1

Y2

W2

G

O

B

C

W1

1st Stage

Compressor

Contact

2nd Stage

Compressor

Contactor

Auxiliary

Heat Relay

(stage 2)

1st Stage

Heat Relay

Fan Relay

Tr

an

sf

or

m

er

C

om

m

on

(re

qu

ire

d)

24 VAC

Neutral

Hot

120 VAC

Fan runs intermittently

or when system is off.

Wiring Diagram for 2 Stage Heat, 2 Stage Cool

Store this

Booklet for

Future reference

Braeburn Systems LLC, as an Energy Star partner
has determined that this product meets the Energy Star
Guidelines developed by the U.S. Environmental
Protection Agency & the U.S. Department of Energy for
maximum energy efficiency.

For more information on energy

savings, go to

www.energystar.gov

© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5100-100-007

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are

due to faulty material or workmanship for a period of five years after the original date of

purchase by a professional service technician. This warranty and our liability does not apply to

batteries, nor does it include damage to merchandise or the thermostat resulting from

accident, alteration, neglect, misuse, improper installation or any other failure to follow

Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat

under warranty provided it is returned postage prepaid to our warranty facility in a padded

carton within the warranty period, with proof of the original date of purchase and a brief

description of the malfunction. This limited warranty does not include the cost of removal or

re-installation.

This warranty gives you specific legal rights and you may also have other rights that vary from

State to state or province to province. Answers to any questions regarding our limited warranty

May be obtained by writing our corporate offices.

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)

WARRANTY FACILITY: Braeburn Systems LLC

Attn.: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538