5100_14_bck.pdf, Store this booklet for future reference, Troubleshooting – Braeburn 5100 User Manual
Page 8: Wiring diagram, Symptom potential solution, Wiring diagram for 2 stage heat, 2 stage cool
14
TROUBLESHOOTING
6
cont.
SYMPTOM
POTENTIAL SOLUTION
Fan continues to run all
the time whether the
system is on or off.
Check that the fan control switch is in the
AUTO position. This
will allow the fan to run only when the heating or cooling system
is turned on and running.
Check thermostat wiring to make sure that the fan control
wiring is connected to the correct terminals on the wiring
terminal block. See Installation and Wiring Diagram sections of
this manual.
Fan continues to run in
cooling mode when the
system has turned off.
The Residual Cooling Fan Control Feature can allow up to a 90
second fan delay after cooling system shutdown for energy
efficiency gains. The default setting is 60 seconds. This can be
changed to disable the feature or shorten the time period if
desired. See Setting Residual Cooling Fan Feature section of
this manual.
Fan switch is in recirculate
®
mode.
The thermostat does
not allow me to program
each day separately.
Change from Weekday-Weekend to 7 Day Mode
(see section 4.4).
System turns on
prior to the end of a
setback period.
Thermostat is in Adaptive Recovery Mode – see section 5.6.
WIRING DIAGRAM
7
NOTE:
Eliminate connection to Y2 for units with single stage cooling.
R
Y1
Y2
W2
G
O
B
C
W1
1st Stage
Compressor
Contact
2nd Stage
Compressor
Contactor
Auxiliary
Heat Relay
(stage 2)
1st Stage
Heat Relay
Fan Relay
Tr
an
sf
or
m
er
C
om
m
on
(re
qu
ire
d)
24 VAC
Neutral
Hot
120 VAC
Fan runs intermittently
or when system is off.
Wiring Diagram for 2 Stage Heat, 2 Stage Cool
Store this
Booklet for
Future reference
Braeburn Systems LLC, as an Energy Star partner
has determined that this product meets the Energy Star
Guidelines developed by the U.S. Environmental
Protection Agency & the U.S. Department of Energy for
maximum energy efficiency.
For more information on energy
savings, go to
www.energystar.gov
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5100-100-007
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are
due to faulty material or workmanship for a period of five years after the original date of
purchase by a professional service technician. This warranty and our liability does not apply to
batteries, nor does it include damage to merchandise or the thermostat resulting from
accident, alteration, neglect, misuse, improper installation or any other failure to follow
Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat
under warranty provided it is returned postage prepaid to our warranty facility in a padded
carton within the warranty period, with proof of the original date of purchase and a brief
description of the malfunction. This limited warranty does not include the cost of removal or
re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from
State to state or province to province. Answers to any questions regarding our limited warranty
May be obtained by writing our corporate offices.
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)
WARRANTY FACILITY: Braeburn Systems LLC
Attn.: Warranty Department
2215 Cornell Avenue
Montgomery, IL 60538