Technical specifications – BASO G95 Series Single Operator Valve User Manual
Page 5
BASOTROL Single Operator Valve Installation Instructions 5
Technical Specifications
Product
G95 Series BASOTROL Single Operator Valve
Maximum Operating Pressure
0.5 psi (35 mbar)
Permissible Ambient (Surface)
Temperature
-20 to 175°F (-29 to 79°C) nitrile diaphragm
-40 to 175°F (-40 to 79°C) silicone diaphragm
Available Magnetic Operator Cover
Styles
Aluminum side conduit hub
Aluminum top conduit hub
Aluminum top without conduit hub
Aluminum side outlet with eyelet
Plastic with 1/4 in. (6.35 mm) male quick-connect terminals
Electrical Rating
25 VAC, 60 Hz, 0.3 ampere draw
120 VAC, 60 Hz, 0.05 ampere draw
240 VAC, 60 Hz, 0.03 ampere draw
12 VDC, 0.5 ampere draw
Bottom Adjust Regulators:
3 to 6 in. W.C. (7.5 to 15 mbar)
8 to 12 in. W.C. (20 to 30 mbar)
Regulator Adjustment Range
Top Adjust Regulators:
3 to 6 in. W.C. (7.5 to 15 mbar)
6 to 12 in. W.C. (15 to 30 mbar)
Inlet Pipe Size
1/2 in. NPT
Outlet Pipe Size
1/2 in. or 3/4 in. NPT
Pilot Outlet
1/8 in.-27 NPT, 1/4 in. cc also available
Wiring Connections
1/4 in. (6.35 mm) male quick-connect or 30 in. (762 mm) lead wires (other lengths are optional)
Types of Gas
Natural or Liquefied Petroleum (LP)
Accessories
Conversion Kits:
Natural Gas to LP Gas:
LP Gas to Natural Gas:
Top Adjust Regulator
Bottom Adjust Regulator
Top Adjust Regulator
Bottom Adjust Regulator
Y71GF-4
Y71GF-3
Y71QH-2
Y71QH-3
Packaging
Bulk pack supplied to original equipment manufacturer (individual pack optional).
Bulk Pack Quantity
32 per carton
Bulk Pack Weight
41 lb (19 kg) per carton
Agency Listings
CSA Certificate Number 229521-1656041
Specifications Standards
ANSI Z21.78, CSA 6.20
Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry
and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty.
Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end
user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products
LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products.
Refer to the G95 Series BASOTROL® Single Operator Valve Product Bulletin (BASO-PB-G95) for necessary information on operating and performance
specifications for this product.
1007 South 12th Street
PO Box 170
Watertwon, WI 53094
www.baso.com
1-877-227-6427 (1-877-BASOGAS)
Printed in U.S.A.