Technical specifications – BASO G292 Series Dual Pilot Gas Valve User Manual
Page 4
4 G292 Series BASO Dual Pilot Gas Valve Installation Instructions
Technical Specifications
Product
G292 Series BASO Dual Pilot Gas Valve
Maximum Operating
Pressure
0.5 psi (35 mbar)
Valve Body
Aluminum
Permissible Ambient
(Surface) Temperature
-30 to 175
°F (-34 to 79°C) without rotor B valve
32 to 175
°F (0 to 79°C) with rotor B valve
Recommended
Thermocouple Lead
Lengths
K15: 12 to 48 in. (305 to 1,220 mm)
K16: 12 to 72 in. (305 to 1,830 mm)
K19: 18 to 72 in. (457 to 1,830 mm)
Body Connections
1/2 in. NPT Inlet x 1/2 in. NPT Outlet
1/2 in. NPT Inlet x 3/4 in. NPT Outlet
Types of Gas
Natural, Liquefied Petroleum (LP), and LP gas-air mixtures
Packaging
Bulk pack supplied to original equipment manufacturer (individual pack optional)
Bulk Pack Quantity
32
Bulk Pack Weight
64 LB (29 kg)
Agency Listing
CSA (AGA/CGA) Certificate Number 229521-1656050
Specification Standards
ANSI Z21.78, CSA 6.20
UL Standard 372
Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.
Refer to the G292 Series BASO Dual Pilot Gas Valve Product Bulletin (BASO-PB-G292) for necessary information on operating and
performance specifications of this product.
1007 South 12th Street
PO Box 170
Watertown , WI 53094
www.baso.com
1-877-227-6427 (1-877-BASOGAS)
Published in U.S.A.