Store the comparator limits into a specified ID memory.
Command
M L
,
1 2 3
,
+ 1 0 1 0
,
+ 9 9 0 C L
F
Reply
AK
ID number: Maximum 6 digit
Upper limit:
Maximum 9 digit including sign
Lower limit:
Maximum 9 digit including sign
Store the total count and number of additions into a specified ID memory.
Command
M A
,
1 2 3
,
+ 6 7 8 9
,
1 2 3 C L
F
Reply
AK
ID # Upper Limit Lowe Limit
ID # Total Count # of Additions
ID number: Maximum 6 digits
Total count:
Maximum 9 digits including sign
Number of addition: Maximum 8 digits
Request the scale to reply with the F-Function settings.
Command
? F C , 0 5 0 1 C L
F
Request the setting of f-05-01.
Reply
F C , 0 5 0 1
,
0 C L
F
f-05-01 = 0
Command
? F C C L
F
Request to reply with the setting of the next F-Function.
Reply
F C , 0 5 0 2
,
0 C L
F
f-05-02 = 0
Store the specified F-Function setting value
Command
F C ,
0 5 0 3
,
+ 1 2 3 4 C L
F
Set “1234” as the Upper limit.
F-# Setting value
F-# Setting value
F-Function number: 4 digits
Setting value:
Maximum 8 digits including sign.
Reply
AK
Command
O N C L
F
Start with new settings.
Reply
AK
Having finished the "FC" command, send the "ON" command to start the scale with
new settings. The scale replies
54