beautypg.com

Kofax Communication Server 10.0.0 User Manual

Page 97

background image

Environment Guide

Version 10.00.00

© Copyright Kofax. All information is subject to change without notice.

97

LED status
Left Right

TC23.3

TC24

TC26

off yellow

interface reset, not yet booted, or not configured at
all

steadily red off

interface initialized, but the line not active
(line disconnected or out of order)

steadily red steadily green

interface initialized, the line is connected
but not functioning properly

TC24: not synchronous
TC23/TC26: not used

off steadily green

interface initialized, line connected and active

flicker green steadily green

active transmission via this line

TC26 interface only

On device controls and display

Model 305 features a 16x2 character display and two pushbuttons on the front panel. On the LCD, various

status information are displayed. The buttons are used to navigate through menus, to set the IP address,

net mask and gateway of LAN1, and to reboot the device.

Startup display

On startup Model 305 displays following information:

TC16 BIOS Version + IP-Address

TC/LINUX Version

Afterwards you will see on the display that the Model 305

is waiting for the KCS server. As soon as TCOSS

connects to the Model 305, you will get two more display screens for updating the software and for

initializing the DSPs.

Standard display

By default Model 305

displays either ``Not connected'' followed by the IP address, or the current line

statistics. Line statistics is displayed in the form ``/'',

for example ``12/32 lines'' means that out of a total of 32 configured lines, 12 are active.

If there is no button pressed for a certain time, Model 305

will return to standard display automatically.

Menu

Pressing mode at any time (except directly after booting) brings up the menu. Pressing mode again cycles

through the menu items, pressing Set selects a menu item. Pressing mode after the last menu item returns

to standard display. The menu structure is outlined below: