KEYENCE OP-87524 User Manual
Instruction manual, Telecentric macro lens mounting stand, Checking the package contents introduction
2012
11938E 1012-1 96M11938
Telecentric Macro Lens Mounting Stand
OP-87524
Instruction Manual
Read this manual before using the product in order to achieve maximum performance.
Keep this manual in a safe place after reading it so that it can be used at any time.
The OP-87524 is supplied with the following items. Check that all are included in the package.
F
Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
F
Front Metal Bracket for Lens Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
F
Rear Metal Bracket for Lens Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
F
Mounting Screws (M4×L16mm double sems screw ×8) . . . . . . . . . . . . . . . . . . . . . 1 set
F
Instruction Manual (this document)
* We make every effort to ensure products reach our customers without any damage.
However, if you encounter any defective, damaged, or missing parts, please contact
your nearest KEYENCE sales office.
This is the instruction manual for the Dedicated Mounting Stand for the Telecentric Macro
Lens CA-LM0307. When using the CA-LM0307, it is necessary to fix the Lens Main Unit to
the equipment using this item or a stand of similar structure.
Symbols
This manual uses the following symbols so that you can recognize important messages at
a glance. Please read it in its entirety..
Refer to the diagram below to assemble the Stand and fix it to the Telecentric Macro Lens.
1.
To tighten the bracket for fixing the Lens, tighten the round holes first, then
tighten the elliptical holes.
When attached to the CA-LM0307, CV-035C/M and XG-035C/M
When attached to the CA-LM0307, CV-200C/M, CV-H035C/M, CV-H100C/M,
CV-H200C/M, CV-H500C/M, XG-200C/M, XG-H035C/M, XG-H100C/M, XG-H200C/M
and XG-H500C/M
Stand weight: approximately 160g
Checking the Package Contents
Introduction
It indicates a situation which, if not avoided, could result in product
damage as well as property damage.
Installation
NOTICE
1
1
Recommended tightening torque:
80 to 100 cN·m (between Stand and Bracket)
Stand Main Unit Fixing recommended screw:
M4 double sems L-16 ×4
(fix the Stand Main Unit by the lower portion.)
When installing the Stand Main Unit to the equipment, ensure
insulation from the equipment. Since the Lens and the Camera have a
Case Grounding, if it is connected directly without insulation when
there is a difference in potential or where there is noise, it may cause
damage to or malfunction of the device.
Dimensions
NOTICE
68
(34.5)
41.2
(131.7)
(48.3)
70
6.7
130.7
80
0.2
25
60
Stand Main Unit screw positions
LENS Center
Unit: mm
(60)
(131.7)
130.7
6.7
80
60
25
0.2
Stand Main Unit screw positions
41.2
(34.5)
68
70
LENS Center
Unit : mm
96M11938