KEYENCE OP-87337 User Manual
Instruction manual, Macro lens mounting stand, Checking the package contents introduction
Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
11649E 1031-1 96M11649
Printed in Japan
Macro Lens Mounting Stand
OP-87337
Instruction Manual
Read this manual before using the product in order to achieve maximum performance.
Keep this manual in a safe place after reading it so that it can be used at any time.
The OP-87337 is supplied with the following items. Check that all are included in the package.
F
Stand (Insulation installation plate attached) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
F
Metal Bracket for Lens Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
F
Plastic bracket for Lens end mounting (Holder, Bracket assembly complete) . . . . 1 set
F
Mounting screws (M4 x L16 mm 6-hole bolt double sems screw x 4) . . . . . . . . . . 1 set
F
Instruction Manual (this document)
* We make every effort to ensure products reach our customers without any damage.
However, if you encounter any defective, damaged, or missing parts, please contact
your nearest KEYENCE sales office.
This is the instruction manual for the Dedicated Mounting Stand for the Line Scan Camera
Macro Lens CA-LM0210/CA-LML0210. When using the CA-LM0210 or CA-LML0210, it is
necessary to fix the Lens Main Unit to the equipment using this item or a stand of similar
structure.
Symbols
This manual uses the following symbols so that you can recognize important messages at
a glance. Please read it in its entirety..
Refer to the diagram below to assemble the Stand and fix it to the Macro Lens.
1.
Temporarily fix the Plastic bracket for Lens end mounting to the Stand Main Unit,
after installing the Lens Mounting bracket for procedure 2, tighten using the
recommended torque.
2.
To tighten the bracket for fixing the Lens, tighten the round holes first, then
tighten the elliptical holes.
When attached to the CA-LM(L)0210, XG-HL02M/HL04M/HL08M
Stand weight: approximately 980g
Checking the Package Contents
Introduction
It indicates a situation which, if not avoided, could result in product
damage as well as property damage.
Installation
NOTICE
1
2
2
Recommended tightening torque:
1.0 to 1.3N m (Lens/ Stand Main Unit same)
Stand Main Unit Fixing recommended bolt:
M5 Hexagonal hole bolt double sems L-20 mm and
over x 4 (fix the Stand Main Unit by the lower portion.)
When installing the Stand Main Unit to the equipment, use the
included Insulation Installation Plate to ensure insulation from the
equipment. Since the Lens and the Camera have a Case Grounding, if
it is connected directly without insulation when there is a difference
in potential or where there is noise, it may cause damage to or
malfunction of the device.
Dimensions
NOTICE
58
37.6
68
79
94
62
141.1
(142.4)
34.75
(50)
LENS Center
Stand Main Unit screw positions
7.6
(30)
96M11649