Dimensions, Static elimination ability chart, Caution – KEYENCE SJ-HS/HW/HM User Manual
Page 2: Removing the air booster, Supplying air, With sj-h series attached
2
7
Use M5 screws to secure the SJ-H Series in the
installation location.
■
Removing the air booster
1
Remove the air booster side support B.
2
Remove the straight air booster (wide angle booster)
through the groove on the static elimination bar guide rail.
The straight air booster (wide angle booster) can
be removed as a single unit by using a narrow,
slotted screwdriver or similar small tool to unlock
the lock.
3
Remove the air booster side support A.
■
Supplying air
As shown in the diagram below, install the joint to the air supply opening in order to supply air.
• Be sure to use a joint tightening torque of 1.2 N
•m (12 kgf•cm) or less. Otherwise
an accident or malfunction may result.
• Be sure to supply air from both sides (2 locations).
• Please contact the nearest KEYENCE office when opening and closing the air duct.
Recommended joint
We recommend using the tube fitting (tube diameter
φ10 mm) joint manufactured by Nihon Pisco.
• Use a joint with a tube diameter of
φ10 mm for the air booster.
• When supplying air to multiple units at the same time, supply air to each air booster. If an attempt is
made to supply air to multiple SJ-H Series unit from one air supply source, sufficient air supply may not
be obtained.
Dimensions
■
With SJ-H Series attached
Static Elimination Ability Chart
■
Static elimination area and static elimination time
The following examples show the relationship between the time required for static elimination on the
target and the operating distance from the target to the static elimination bar.
●
Straight air booster
●
Wide angle booster
■
Relationship between air pressure and flow according to static elimination bar length
The relationship between the supplied air flow and the air pressure changes depending on the static elimina-
tion bar length.
Refer to the typical examples and select an air supply device (compressor) that will provide sufficient air flow.
●
Straight air booster
●
Wide angle booster
■
Relationship between static elimination speed and operating distance depend-
ing on air pressure
The relationship between the static elimination speed and the static elimination bar operating dis-
tance is different depending on the air pressure.
Refer to the typical examples and adjust the air pressure.
●
Straight air booster
Total length A
Mounting pitch B Mounting pitch C
SJ-H036
451
432
400
SJ-H060
671
652
620
SJ-H084
911
892
860
SJ-H108
1151
1132
1100
SJ-H132
1391
1372
1340
SJ-H156
1631
1612
1580
SJ-H180
1871
1852
1820
SJ-H204
2111
2092
2060
SJ-H228
2351
2332
2300
SJ-H252
2591
2572
2540
SJ-H300
3071
3052
3020
Be sure to secure the end unit with four M5 screws.
Note
Reference
Caution
R3/8
Rc3/8
R3/8
Rc3/8
Tube diameter
φ10mm: PC10-03
Note
21
*3
38
*2
70
*1
18
23
30
29
42
A
B
C
4
122
Straight air booster
*
Wide angle booster
*
Sealing unit
SJ-H036*
*1
90mm
*2
21mm
*3
No modular socket
* The straight air booster and the wide angle booster cannot be mounted at the same time.
(R24)
Rc3/8
Rc1/8
(R24)
102 (82)
51
27.5
Rc3/8
27.5
Rc1/8
Bar (left)
Bar (Right)
150
300
450
300
600
1500
600
150 300 450 600mm
900
1200
0.8sec
1.0sec
0.4sec
0.6sec
mm
Measurement conditions:
Elimination time from
±1000 V to ±100 V
The 150
× 150 mm plate monitor (20 pF) is used.
SJ-H060 + Straight air booster is used. No downflow.
Air supply / SJ-H060: 0.5 MPa, Straight air booster: 0.5 MPa
Operating area and time
(33Hz)
150
300
450
300
600
1500
600
150 300 450 600mm
900
1200
2.0sec
3.0sec
0.5sec
1.0sec
mm
150
300
450
300
600
600
150 300 450 600mm
900
1200
2.0sec
3.0sec
0.5sec
1.0sec
mm
Measurement conditions:
Elimination time from
±1000 V to ±100 V
The 150
× 150 mm plate monitor (20 pF) is used.
SJ-H060 + Wide angle booster is used. No downflow.
Air supply / SJ-H060: 0.1 MPa, Wide angle booster: 0.5 MPa
Measurement conditions:
Elimination time from
±1000 V to ±100 V
The 150
× 150 mm plate monitor (20 pF) is used.
SJ-H060 + Wide angle booster is used. No downflow.
Air supply / Main body: none,
Wide angle booster: 0.25 MPa (50
/min per electrode)
Operating area and time
(33Hz)
Operating area and time
(10Hz)
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
0
0.1
0.2
0.3
0.4
0.5
Supplied flow[N /min]
Air pressure[MPa]
SJ-H036
SJ-H060
SJ-H084
SJ-H108
SJ-H132
SJ-H156
SJ-H180
SJ-H204
SJ-H228
SJ-H252
SJ-H300
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
0
0.1
0.2
0.3
0.4
0.5
Supplied flow[N /min]
Air pressure[MPa]
SJ-H036
SJ-H060
SJ-H084
SJ-H108
SJ-H132
SJ-H156
SJ-H180
SJ-H204
SJ-H228
SJ-H252
SJ-H300
0
1.5
2.0
2.5
3.0
3.5
0
300
600
900
1200
1500
0.1MPa
0.2MPa
0.3MPa
0.4MPa
0.5MPa
1.0
0.5
Operating distance[mm]
Static elimination time[sec]
Measurement conditions:
Elimination time from
±1000 V to ±100 V
The 150
× 150 mm plate monitor (20 pF) is used.
SJ-H060+ Straight air booster is used. No downflow.
Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved.