Heck, Eigh, Bsolute and – Holtgreven GSE-665 User Manual
Page 49: Ercentage, Peration
C
H A P T E R
6 : A
D D I T I O N A L
O
P E R A T I N G
M
O D E S
41
C
HECK
W
EIGH
A
BSOLUTE AND
P
ERCENTAGE
O
PERATION
The standard check-weigh operation is designed to check the weight of an
item against a given standard or target weight. In the check weigh absolute
mode, values are entered as target limits. In the check weigh percent mode,
the values are entered based on percentage.
S
ET THE
H
I AND
L
O WEIGHTS
(460)
1. Press
[SELECT] until prompt = “mName SETUP”.
2. Press
[TARE] prompt =”10.00 High” (by default)
3. Use
the
[PRINT] key to enter a number ( [UNITS] key moves
placeholder over 1 spot)
4. Press
[TARE] prompt = “5.00 Lo”.
5. Repeat steps 2 – 4 to enter in low value
6. Press
[TARE] indicator returns to previous display mode.
U
SE
C
HECK
W
EIGH
(460)
1. Press
[SELECT] until prompt = “mName START”
2. Press
[ENTER]. The display will return to the weigh mode.
3. To stop check-weighing, press [SELECT] until prompt = gross mode.
Note: if your weight is greater than your hi weight then the prompt = “OVER” is
displayed. If your weight is less than your Lo weight the prompt = “UNDER” is
displayed. If your weight is between the Hi and Lo then prompt = “GOOD” is
displayed.
S
ET THE
H
I AND
L
O WEIGHTS
(465,560,562
AND
660 S
ERIES
)
1. Press
[TARGET] or [F2] prompt = “10.00 Hi”. (by default)
2. Key in the desired high value weight.
3. Press
[ENTER] prompt = “5.00 Lo”. (by default)
4. Key in the low value weight.
5. Press
[ENTER] indicator returns to previous display mode.
U
SE
C
HECK
W
EIGH
1. Press
[F1] to start check-weighing
2. Add your weight to the scale.
3. Press