Messages and emergency operation
Display
a) Reset to initial function
b)
Function bridged (emergency
operation - no safety function)
LED - OFF / Compressor - ON
Winding temperature too high.
LED ON / Compressor OFF
Switch 2 Off
Reset
Reset
2
Switch 3 Off
Reset
Status message
Reset not possible
Compressor starts automa-
tically after preheating the
lube oil to +25°C, but at
the latest after 30 min.
pre-heating time
3
Compressor starts up immedi-
ately.
LED OFF
Compressed gas temperature
too high. LED ON / Compressor
OFF
Compressor starts up through
machine control. LED flashes
Switch 1 Off
Reset
+
Reset
Fault message
Possible after cooling down
to operating temperature
Possible without cooling down
to operating temperature
1
Fault message
Compressor starts up immedi-
ately.
LED OFF
Possible after cooling down
to operating temperature
Compressor starts up through
machine control. LED flashes
Possible without cooling down
to operating temperature
Oil temperature too low.
LED ON / Compressor OFF
Compressor starts up through
machine control. LED flashes
LED - OFF / Compressor - ON
Switch 3 Off
Reset
Status message
Reset not possible
Compressor starts automa-
tically after cooling down.
3
Oil temperature too high.
LED ON / Compressor OFF
Compressor starts up through
machine control. LED flashes
+
+
+