Torque ranges – Checkline CAP-TNP User Manual
Page 2
- 2 -
1.0 I
NTRODUCTION
Thank you for choosing the CAP-TNP digital torque tester, with proper care this
unit will provide many years of reliable service.
The CAP-TNP torque meter is a portable device that can be used as a quality
assurance tool for various applications that requires turning (both opening and
closing) and twisting.
Some fields that can utilize this equipment are:
• Pharmaceutical,
• Food and Beverage
• Cosmetic products
Built with internal rechargeable batteries, the CAP-TNP can operate as a portable
DC device or thru the universal AC adapter. Designed with a small footprint it can
easily be moved around the shop floor or the laboratory to maximize use.
The programmable HI-LO set points make this unit ideal for pass-fail testing in a
production environment.
1.1 Complete
Kit
Each package includes the following:
• Operations Manual
• Software Manual
• Software Installation Disk
(Digitorq Software)
• Warranty Cards
• USB A to USB B communication cable
• Universal AC adapter (100-240 VAC)
• Set of 30 mm chuck pins (4 pieces)
IMPORTANT: Upon receiving the unit, please check for any obvious physical
damage that may have occured during shipping. If any damage is found, please
notify your carrier immediately before shipping the unit back to Electromatic for
repairs and inspections.
WARNING
Do not test products that are filled with liquid contents. The CAP-TNP
torque tester is not protected from liquid spills that may come from the
tested product.
- 15-
5.0 S
PECIFICATIONS
OverloadProtection
150%
Sample Diameter Range (min to max) 0.39" to 7.48" (10–190 mm)
Overload display
Display "OVR" on LCD (blinking on/off)
Main display
4-digit LCD display
Character height 12mm
Sub display
3-digit LCD display
Character height 7mm
Comparator display
Hi, GO, Lo LED Indicators
Accuracy
± 0.5% full scale
Open mode
Max vale when opening.
Displays max counter clockwise torque.
Close mode
Max value when closing.
Displays max clockwise torque
Average mode
Real time display. Displays max torque in real time
Display Update
1, 2, 4 or 8 updates/second, user-set
Sampling Rate
1000 times/second
Memory Storage
1000 data points (max)
Statistic process
Average value, max value and min value
Data output
USB 1.1
PC software
Digitorque software
Power
Built in nickle hydride battery or Auto-ranging AC
adapter (AC 100 — 240V)
Dimensions
12.60" x 8.94" x 4.96" (320 x 227 x 126mm) L x W x H
Operation Temp.
32 - 104°F (0 - 40°C)
Battery Life
8 hours after full charge
Battery Recharge Time
Max. 16 hours
Battery Type
NiMH
CAP-TNP-2
0-2.000 Nm
0-200.0 Ncm
0-20.39 Kgcm
0-17.70 Lbin
CAP-TNP-5
0-5.000 Nm
0-500.0 Ncm
0-50.99 Kgcm
0-44.25 Lbin
CAP-TNP-10
0-10.00 Nm
0-1000 Ncm
0-102.0 Kgcm
0-88.50 Lbin
Model Capacity Resolution
0.001 Nm
0.1 Ncm
0.01 Kgcm
0.01 Lbin
0.001 Nm
0.1 Ncm
0.01 Kgcm
0.01 Lbin
0.01 Nm
1 Ncm
0.1 Kgcm
0.1 Lbin
Torque Ranges