beautypg.com

Checkline WTTM-GEN1 User Manual

Page 2

background image

– 2 –

1.0

I

NTRODUCTION

Thank you for selecting the CHECK•LINE WTTM Wire Terminal Pull Tester for
your requirements. With correct use and proper care this product should provide
many years of precise and accurate testing. Please read the entire operation manual
thoroughly before using this instrument for the first time. The information contained
herein will help users to achieve accurate and repeatable results as well as prevent
damage through improper set-up or operation.

This instrument is designed for measuring tensile strength of soldered or solder-free
cable joints with end sleeves, pins, solder pins or similar wire terminal components
in the field of quality control or design validation.

Safety Precautions

Wear appropriate eye protection at all times.

The load cell can be damaged if the internal measuring system is over-
loaded. Do not exceed the maximum measuring limit of 50 Kg (110 lbs.,
500N) or 100 Kg (220 lb., 1000N), respectively

Transport and store the instrument with care. This reduces the risk of dam-
age to the load cell or other minor mechanical problems which can cause
inaccurate measurement results.

Operate the instrument in appropriate environments only. The instrument
is equipped with a temperature compensation for a temperature range of
32 to 120 °F (0° to 40°C) and should be used in this temperature range
only. Do not expose this device to liquid or operate in high-humidity envi-
ronments.

– 19 –

A

PPENDIX

: P

ULL

T

EST

S

PECIFICATIONS FOR

UL, MIL

AND

SAE

Size of Conductor

UL 486A Table 12.1

SAE AS7928 Table II

AWG

(mm2)

Pounds

(N) Pounds

(N)

30

0.050

1–1.5

6.7

N/A

N/A

28

0.080

2

8.9

N/A

N/A

26

0.130

3

13.4

7

3.12

24

0.200

5

22.3

10

44.5

22

0.324

8

35.6

15

66.8

20

0.519

13

57.9

19

84.6

18

0.823

20

89.0

38

169.1

16

1.310

30

133.5

50

222.5

14

2.080

50

222.5

70

311.5

12

3.310

70

311.5

110

489.5

10

5.261

80

356.0

N/A

N/A

Pull Test Specifications for UL, MIL and SAE