2 .0 U
N PACK I N G
& C
ON T EN T S
Remove the unit carefully and check the unit appears undamaged in shipment.
Check to see that all of the supplied items are contained in the box (see below).
Retain packaging materials in the case that the unit needs to be returned to the manu-
facturer or distributor.
■ Main instrument table
■ Separate hand lever with ball end
■ 9V DC battery charger 100 to 240 VDC (50 to 60Hz) with Euro/US/UK
plug adaptor
■ Operating instruction manual
■ Connection cable for RS232C (WTT-110RS model ONLY), not shown
Lever
Wire CLAMP Fixture
Wire TERMINAL Fixture
– 18 –
1 4 .0 S
PECI FI CAT I ON S
Measuring Range*
0–50 Kg / 0–110 lbs / 0–500N
(units selected via keypad)
Resolution
0.01Kg / 0.1 lbs / 0.1 N
Terminal adapter
slot width (mm)
0.5, 0.8, 1.0, 1.4, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0
Accuracy
±0.5% F.S. or better
Operating Mode
Continuous
Displays actual value in Kg, lbs. or N
Peak-Hold
Displays peak value in Kg, lbs. or N
Wire Diameter
SAE AS7928 II
AWG 8. . .30
IEC 60352-2
Cross section 0.05. . .10mm2
Maximum
0.236" (6mm)
Overload
200% Full Scale (LCD indicator at 120%)
Display
LCD, 4–1/2 digit, 12mm high
Memory
Peak Value
Power Supply
Internal NiCd battery, supplied with
AC adapter/charger
(100-240V/50-60 Hz)
Temp. Range
Operating 32
to104
°F
(0 to 40 °C)
Storage
–4 to 140 °F (–20 to 60 °C)
Weight, approx.
30.8 lbs. (14 Kg)
Dimensions
14.2" x 6.3" x 2.95" (360 x 160 x 75mm)
Material
Anodized aluminum, steel and stainless steel
* Low-range model available on special order basis.
Model WTT-110RS Only
Interface
Serial
2400 KB / 8 / N /1/ None (selectable baud rate)
Analog
0-1V DC