Ucm setup parameters – Blue Sky UCM User Manual
Page 20
Blue Sky Energy – Universal Communication Module
19
3) Force Single Coil (0x05)
Query Packet:
Slave address | Function code 0x05 | MSB coil address | LSB coil address |MSB force data, don’t care |
LSB force data, don’t care | LSB CRC | MSB CRC
Response Packet:
Slave address | Function code 0x05 | MSB coil address | LSB coil address |MSB force data, don’t care |
LSB force data, don’t care | LSB CRC | MSB CRC
FORCE COILS
PDU ADDRESS
LOGICAL COIL #
DESCRIPTION
0x0013 20
Start
Equalize
0x0014 21
Stop
Equalize
0x0015
22
Clear Max. Battery Volts Detected
0x0016
23
Clear Min. Battery Volts Detected
0x0017
24
Clear Total Charge Amp-Hours
0x0018
25
Clear Lifetime Battery Discharge Amp-Hours
0x0019
26
Set Charge Efficiency to Auto Mode
0x001A
27
Set Charge Efficiency to Fixed Mode
0x001B
28
Set Aux. Out Mode to Volts
0x001C
29
Set Aux. Out Mode to Amp-Hours
0x001D
30
Restore Charge Controller Defaults
TABLE 6
UCM SETUP PARAMETERS
¾
The UCM has various setup parameters all of which are preconfigured at the factory. All setting are stored either in nonvolatile
memory, DIP switches or jumpers such that all settings are retained following a loss of power.
As Shipped Factory Default Settings
Basic TCP/IP Communication
FTP File Transfer
• IPv4 IP Address ......................................... 192.168.1.235
• Server address ......................................................... ―blank―
• Subnet Mask .............................................. 255.255.255.0
• User Name ............................................................... ―blank―
• Gateway IP Address ................................. 192.168.1.1
• Password ................................................................... ―blank―
• IP-A (force use of comm defaults) ............ off
• Hours Between Uploads .......................................... Disabled
Datalogging UCM
logon
• Hours in Log Period ................................... Disabled
• Password................................................................... admin
MODBUS
• Address / Unit Identifier ............................. 1 (AD0 ― AD7 all off)
• RS-485 Duplex Mode ............................................... Half Duplex
• RS485 DataBits/Parity/StopBits ............... 8/Even/1 (Baud1/Parity off) • RS-495 Baud rate ..................................................... 19.2K (baud0 off)
Misc.
• Location Name Reminder ......................... MY SOLAR SYSTEM
Restoring As Shipped Factory Default Settings
1. Remove UCM power
5. Set all 12 DIP’s shown in Figure 4 to OFF
2. Set DIP’s AD0 ― AD7 shown in Figure 4 to all ON
6. Install two jumper plugs
A-to-A’ and B-to-B’
shown in Figure 4
3. Restore UCM power for 10 seconds, confirm power LED blinking
7. UCM is now restored to As Shipped Factory Default Settings
4. Remove UCM power
)