Installation specification, 4 technical data – STIEBEL ELTRON Accelera 300 User Manual
Page 26

26
| ACCELERA® 300 HEAT PUMP WATER HEATER
WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
SPECIFICATION
16.4 Technical Data
Model
Heat pump water heater
Type
Accelera 300
Part number
222423
Version
With passive defrosting and booster heater
Operating details
Lower application limit for heat pump operation
(air temperature)
°C (°F)
6 (42.8)
Upper application limit for heat pump operation
(air temperature)
°C (°F)
42 (107.6)
Hot water temperature, heat pump
°C (°F)
60 (140)
Hot water temperature, booster heater
°C (°F)
60 (140)
Air flow rate
m
3
/h (CFMs)
550 (324)
Tank capacity
l (Gal)
303 (80.044)
Refrigerant
R 134a
Refrigerant / filling weight
g (oz)
900 (32)
Water heater height (minimum)
mm (inch)
1865 (73.43)
Water heater height (maximum)
mm (inch)
1903 (74.92)
Water heater diameter
mm (inch)
660 (25.98)
Dimension when tilted incl. packaging
mm (inch)
2225 (87.60)
Dimension when tilted, excl. top packaging
mm (inch)
2150 (84.65)
Dimension when tilted, excl. wooden pallet and top packaging
mm (inch)
2030 (79.92)
Dimension when tilted, excl. packaging
mm (inch)
1990 (78.35)
Weight (dry tank)
kg (lb)
130 (287)
Weight (wet)
kg (lb)
432 (950)
Water connection with adaptor
Union to 3/4"
Condensate drain
3/4"
Condenser
Rollbond safety heat exchanger
Permissible operating pressure, low (cold) side*
MPa (Psi)
0.6 (87)
Permissible positive pressure, high (hot) side*
MPa (Psi)
2.4 (348.1)
Sound pressure level (spl)
dB(A)
55.2
Maximum inlet water temperature
°F (°C)
140 (60)