beautypg.com

Installation installation – STIEBEL ELTRON Accelera 300 User Manual

Page 16

background image

16

| ACCELERA® 300 HEAT PUMP WATER HEATER

WWW.STIEBEL-ELTRON-USA.COM

INSTALLATION

INSTALLATION

» Push the packaging foil far enough upwards that the pallet is

freely accessible.

» Remove the water heater carefully with the polystyrene

®

packaging from the pallet.

DANGER Injury from tipping over

The water heater has a high centre of gravity and a

low overturning moment. Ensure that the water heater

does not overturn when you remove it from its pallet.

» Slide the packaging foil far enough upwards to be able to

remove the first polystyrene

®

profiles from the sides. These

polystyrene

®

profiles on the sides are used as installation

aids in the following steps.

26

_03

_01

_13

95

» Separate the lower packaging section at the dividing line.

For this, make an incision of approx. 30 mm (1.25") into both

sides of the dividing line.

6

26

_03

_01

_13

96

» Slightly tilt the water heater.

DANGER Injury from overturning

Secure the water heater against overturning by

getting a second person to support the water heater.

» Push a wooden support underneath the lower part of the

packaging.

» Break out the free semi-shell of the lower section of the

packaging.

» Keep the water heaters slightly tilted.

» Wind out the free leveling foot, but not by more than 30 mm

(1.1").

» Turn the locking nut on the thread of the leveling foot

towards the bottom cover. When the locking nut is tight

against the bottom cover, it stabilizes the leveling foot.