Table 5-12, Mrm resilience main or standby states -28 – Cabletron Systems 3Com PortSwitch Hub User Manual

Page 73

background image

Serial I/f Application

Application Views

3Com PortSwitch Hubs

5-28

Management Module Guide

Main Slot
Displays the slot number of the main port in the pair.

Main Port
Displays the port number of the main port in the pair.

Main State
Displays the state of the main port.

Table 5-12

shows possible values and

descriptions.

SBY Slot
Displays the slot number of the standby port in the pair. You can update this
field using the Mrm Resilience Table Entry view.

SBY Port
Displays the port number of the standby port in the pair. You can update this
field using the Mrm Resilience Table Entry view.

SBY State
Displays the state of the main port.

Table 5-12

shows possible values and

descriptions.

Pair State
Displays the state of the resilient pair. Possible values are Operational and
Invalid. When this field is Operational, all of the parameters in the entry are
valid. When this field is Invalid, either information has been omitted, or the
resilient pair rules are no longer valid because of a change in the configuration
of the device, such as moving a card.

Mod State
Displays the Modification State of the resilient pair. You must set the Under
Mod field in the Mrm Resilience Table Entry view to a value of Under-Mod
before changing the configuration of a pair. The changes are not applied until
this field shows the value Stable.

Pair Action
This field is used to change the state of the pair. Setting a value of Create
configures the pair using the definitions in the entry. Setting Delete removes
the entry from the table and terminates operation of resilience on this pair of
ports. The setting TogglePort swaps the currently active port with the standby
one if, and only if, the standby port has a status of OK.

Table 5-12.

Mrm Resilience Main or Standby States

Value

Description

Failed

Loss of signal to the port

OK

Port is capable of carrying traffic but is in the standby state

OKandActive

Port is active