beautypg.com

9alarm output configuration, Alarm output configuration -10, Figure 14. alarm output configuration screen -10 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual

Page 34: Table 15. alarm output definitions -10, 9 alarm output configuration

background image

EdgeAccess Universal Chassis System

Model 2370 Model User Manual

4-10

4.9

Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 14 and Table 15.

To configure alarms, follow these steps:

1. From the System Configuration menu type

4

, "Alarm Output Configuration," and press .

The Alarm Output Configuration screen appears.

2. Type the number for the alarm you want to set and press .

3. Press to cycle to Major, Minor, or Off, and press .

4. To return to the System Configuration menu, press .

-------------------ALARM OUTPUT CONFIGURATION----------------------------

1) Factory Defaults

2) LOS/CLS Alarm

Off

3) SQL Alarm

Off

4) Configuration Alarm

Off

5) Power/Fan Alarm

Minor

6) Power-On Self Test Alarm

Major

7) BERT Alarm

Minor

Figure 14. Alarm Output Configuration Screen

Table 15. Alarm Output Definitions

Alarm

Description

1) Factory Defaults

Reset all alarms to factory defaults, for values, see Figure 14

2) LOS/CLS

Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off

3) SQL

Squelch (for received signal); default is Off

4) Configuration

Setup errors, including mismatches with other modems; default is Off

5) Power/Fan

Power is low or fan is off; default is Minor

6) Power-On Self Test Modem failed when power was turned on; default is Major
7) BERT

Bit Error Rate Test (BERT) detects data errors; default is Off