9alarm output configuration, Alarm output configuration -10, Figure 14. alarm output configuration screen -10 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual
Page 34: Table 15. alarm output definitions -10, 9 alarm output configuration
EdgeAccess Universal Chassis System
Model 2370 Model User Manual
4-10
4.9
Alarm Output Configuration
Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 14 and Table 15.
To configure alarms, follow these steps:
1. From the System Configuration menu type
4
, "Alarm Output Configuration," and press
The Alarm Output Configuration screen appears.
2. Type the number for the alarm you want to set and press
3. Press
4. To return to the System Configuration menu, press
-------------------ALARM OUTPUT CONFIGURATION----------------------------
1) Factory Defaults
2) LOS/CLS Alarm
Off
3) SQL Alarm
Off
4) Configuration Alarm
Off
5) Power/Fan Alarm
Minor
6) Power-On Self Test Alarm
Major
7) BERT Alarm
Minor
Figure 14. Alarm Output Configuration Screen
Table 15. Alarm Output Definitions
Alarm
Description
1) Factory Defaults
Reset all alarms to factory defaults, for values, see Figure 14
2) LOS/CLS
Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off
3) SQL
Squelch (for received signal); default is Off
4) Configuration
Setup errors, including mismatches with other modems; default is Off
5) Power/Fan
Power is low or fan is off; default is Minor
6) Power-On Self Test Modem failed when power was turned on; default is Major
7) BERT
Bit Error Rate Test (BERT) detects data errors; default is Off