CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual
Page 35
EdgeAccess Universal Chassis System
L357 Gigabit Ethernet Service Unit
4-15
Menu Item
Description
9. Password Reuse Count
Set whether the password must be changed or can
be used again immediately. Values are 0 to 8. 0
means the new password can be the same. 1 to 8
specify how many times the password must expire
before a specific password can be used again.
10. Lockout After Failed Attempts
Set how many times, from 1 to 10, that a user can
try to log in before a lockout; 0 = disabled
11. Lockout Type
Lockout time
Set the type of lockout: Hard requires another user
with admin access to unlock the account on the
User Accounts screen; Timed requires that the
user wait for Lockout time before trying again;
Lockout time is from 0 (none) to 30 minutes
12. Display Lockout Message
13. Lockout Message
Enable or disable and set the message, up to 30
characters, that appears at lockout
14. Lockout Craft Port
Disable access to the serial port to prevent any
unauthorized access; to re-enable the craft port,
run a Telnet session
15. Inactivity Logout time (mins)
Set the time, between 1 and 30 minutes, before
automatic log-out with no activity; 0 = disabled
4.5.7 User Accounts Screen
The User Accounts screen provides options to set values for parameters for specific users. To access
the User Accounts screen, see Figure 26 and follow these steps:
1. From the System Configuration menu type
7
, "Account Configuration," and press
USER ACCOUNTS
Account Access Access Locked
Username State From Level Description Out
admin Enabled UI/SNMPv3 Supervisor Upgrade Account No
Figure 26. User Accounts Screen