4.5.3 Trap Configuration

Traps are messages to alert network management about conditions. The DMM logs the traps and the
DMM or Model 1020 transmits them by SNMP to the network manager. At the Trap Configuration
screen, enable or disable traps individually or use the "Master Trap Control" to enable or disable all
traps. See Figure 20. To configure traps, follow these steps:

1. From the Main Menu, type

1

, "System Configuration," and press . The System

Configuration menu appears.

2. From the System Configuration menu type 3, "Trap Configuration," and press .

3. At the Trap Configuration menu, type the number for a trap and press .

Note: "Master Trap Control" enables or disables all traps. The factory default is Disabled.

4. Press to cycle to Enabled or Disabled, then press .

5. To return to the System Configuration menu, press .

TRAP CONFIGURATION
1) Master Trap Control Disabled

2) Extension Port Link Traps Enabled
3) Remote Fault Received Traps Enabled
4) Link Loss Forwarding Traps Enabled
5) Link Loss Echo Traps Enabled
6) Remote User Port Link Traps Enabled
7) Local User Port Link Traps Enabled
8) Configuration Traps Enabled
9) Power/Fan/Temperature Traps Enabled
10) Cold Start Traps Enabled
11) Side Band Mgmt Channel Traps Enabled
12) Alarm Input Traps Enabled
13) Diagnostics Traps Enabled
14) Authentication Traps Enabled

Figure 20. Trap Configuration Screen

4.5.4 Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 21 and Table 6. To configure alarms, follow these steps:

1. From the Main Menu type

3

, "Alarm Output Configuration," and press . The Alarm

Output Configuration screen appears.

2. Type the number for the alarm you want to set and press .

3. Press to cycle to Major, Minor, or Off, and press .