CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual
Page 31
EdgeAccess Universal Chassis System
L357 Gigabit Ethernet Service Unit
4-11
ALARM OUTPUT CONFIGURATION
1) Factory Defaults
2) Link Down Alarm Off
3) RMTF Alarm Off
4) LLF Alarm Off
5) Configuration Alarm Off
6) Power/Fan/Temperature Alarm Minor
7) SBMC Loss Alarm Off
8) Power-On Self Test Alarm Off
Figure 21. Alarm Output Configuration Screen
Table 6. Alarm Output Definitions
Alarm Description
2) Link Down
Loss of Signal (electrical)/Composite Loss of Signal (optical);
one or both received signals fail; default is Off
3) RMTF
Not available
4) LLF
Link loss forwarded to module; default if Off
5) Configuration
Setup errors, including mismatches with other modules; default
is Off
6) Power/Fan/Temperature
Power is low or fan is off; default is Minor
7) SBMC Loss
SideBand management signal lost; default is Off
8) Power-On Self Test
Module failed when power was turned on; default is Off
Note: You must enable the Alarm Output item on the System Status & Configuration screen for
these settings to take effect.
4.5.5 IP/SNMP Agent Configuration
If the L357 is in a Model 1020, use the SNMP Configuration screen to view and set up the SNMP
parameters on the L357. See Figure 22 and Table 7. To view SNMP parameters, follow these steps:
1. From the System Configuration menu type
5
, "SNMP Configuration," and press
SNMP Configuration screen appears.
2. Type the number for the alarm you want to set and press
3. Type the information or value, and press
4. To return to the System Configuration menu, press