Get-account-from-did / pre-receive-session – FaxBack Port Server RADIUS Support (RFC 2865, 2866) User Manual
Page 18

FaxBack Proprietary and Confidential
Page 18 of 58
User-Name
The account requesting to receive a fax.
Request Packet
Code=Access-Request(1)
Packet identifier=37
Length=47
Authenticator
5A 91 F7 14 E1 63 E8 49 B7 55 3C 98 6C E8 BE C8
Attributes:
Len=18, Type=Vendor-Specific(26), Id=FaxBack(30694)
Len=6, Type=FB-Command(1)
Value=Get-Account(1)
Len=6, Type=FB-Context(2)
Value=For-External-Module(5)
Len=9, Type=User-Name(1)
Value=account
End
◄──
RESPONSE TO PORT SERVER
───
Required
Purpose
RADIUS code
Access-Accept or Access-Reject
Optional
Purpose
FB-Account-Type
Specifies the type of account.
FB-Last-Modified-Time
For an account that is a load-balance group, the value of this
attribute is used to tell the port server if the group membership has
changed since the last time the port server dealt with the group.
FB-Rcv-Email
Account’s receive e-mail address
FB-Rcv-Format
Determines the image type of the fax attachment.
Response Packet
Code=Access-Accept(2)
Packet identifier=37
Length=20
Authenticator
5A 91 F7 14 E1 63 E8 49 B7 55 3C 98 6C E8 BE C8
End
Get-Account-From-DID / Pre-Receive-Session
Sent when the port server needs to know which account is mapped to a DID for inbound routing.
The RADIUS server must respond with an Access-Accept packet that includes an account name
in the “User-Name” attribute as the account that should receive the fax, or an Access-Reject
packet if routing to that DID is not possible. If the DID is known, but receiving is disabled for the
DID for some reason, instead of returning an Access-Reject packet the RADIUS server can return
an Access-Accept packet that includes the “FB-DID-Enabled” attribute with a value of 0.
───
SENT FROM PORT SERVER
──►
Attribute
Value