Handling and storage, Exposure controls/personal protection – Chemtronics Max-Kleen Citrus ES5589 User Manual
Page 4

Max-Kleen™ Citrus
Store in accordance with local regulations. Store in a segregated and approved area.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated
area, away from incompatible materials (see Section 10) and food and drink. Eliminate
all ignition sources. Separate from oxidizing materials. Keep container tightly closed
and sealed until ready for use. Containers that have been opened must be carefully
resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Use appropriate containment to avoid environmental contamination.
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist.
Avoid release to the environment. Use only with adequate ventilation. Wear
appropriate respirator when ventilation is inadequate. Do not enter storage areas and
confined spaces unless adequately ventilated. Keep in the original container or an
approved alternative made from a compatible material, kept tightly closed when not in
use. Store and use away from heat, sparks, open flame or any other ignition source.
Use explosion-proof electrical (ventilating, lighting and material handling) equipment.
Use non-sparking tools. Take precautionary measures against electrostatic discharges.
To avoid fire or explosion, dissipate static electricity during transfer by grounding and
bonding containers and equipment before transferring material. Empty containers retain
product residue and can be hazardous. Do not reuse container.
7. Handling and storage
Handling
Storage
:
:
Distillates (petroleum), hydrotreated light
ACGIH TLV (United States, 3/2012). Absorbed through skin.
TWA: 200 mg/m³, (as total hydrocarbon vapor) 8 hours.
Petroleum distillates
ACGIH TLV (United States, 3/2012).
TWA: 100 ppm 8 hours.
TWA: 525 mg/m³ 8 hours.
OSHA PEL 1989 (United States, 3/1989).
TWA: 100 ppm 8 hours.
TWA: 525 mg/m³ 8 hours.
NIOSH REL (United States, 1/2013).
TWA: 350 mg/m³ 10 hours.
CEIL: 1800 mg/m³ 15 minutes.
OSHA PEL (United States, 6/2010).
TWA: 500 ppm 8 hours.
TWA: 2900 mg/m³ 8 hours.
8. Exposure controls/personal protection
Engineering measures
:
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or
other engineering controls to keep worker exposure to airborne contaminants below any
recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.
Hygiene measures
:
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.
Ingredient
Exposure limits
4/10
ES189/2289L
6/12/2013.