Usage instructions, Environmental impact data – Chemtronics Konform AR CTAR-12 User Manual
Page 2

Performance
Moisture Resistance
Good
Removability
Excellent
Ease of Repair
Excellent
Flexibility
Fair
Adhesion
Excellent
Abrasion Resistance
Excellent
Solvent Resistance
Fair
USAGE INSTRUCTIONS
For industrial use only.
Read MSDS carefully prior to use.
Before applying Konform
AR conformal coatings,
clean circuit boards to remove contamination and
allow to dry. Cleaning may be performed with
Chemtronics Flux-Off
products.
SPRAY APPLICATION: Apply top to bottom,
allowing coating to flow evenly around components.
Rotate PCB 90
° and repeat application. Rotate and
apply coating two additional times, then allow board
to cure. If additional thickness is desired, apply
additional coatings. When using liquid spray with
automatic dispensing equipment, adjustments may
be required in application rate and viscosity.
DIP APPLICATION: Using automatic equipment
or hand immersion technique, slowly immerse PCB
into the coating and remove slowly. Use an average
rate of approximately 1 foot per minute. After
allowing the board to cure, process may be repeated
to achieve desired thickness.
BRUSH APPLICATIONS: Evenly apply coating
to areas desired at thickness required. Allow time
for curing before reapplying to achieve a thick
coating. Use Chemask
to protect components
during conformal coating process.
REMOVAL: After application, cured Konform
AR may be removed by soaking in Chemtronics
Electro-Wash
Two Step.
AVAILABILITY
CTAR-12 11.5 oz. Aerosol
CTAR-1 1 Gallon Liquid
ENVIRONMENTAL IMPACT DATA
(For Aerosol Product)
ENVIRONMENTAL IMPACT DATA
CFC
0.0%
VOC
88.9%
HCFC
0.0%
HFC
0.0%
Cl. Solv.
0.0%
ODP
0.00
CFC, HCFC, CL. SOLV., VOC, and HFC numbers
shown are the content by weight. Ozone depletion
potential (ODP) is determined in accordance with the
Montreal Protocol and U.S. Clean Air Act of 1990.
TECHNICAL & APPLICATION ASSISTANCE
Chemtronics provides a technical hotline to answer
your technical and application related questions.
The toll free number is: 1-800-TECH-401.
NOTE
: This information is believed to be accurate. It
is intended for professional end users having the skills to
evaluate and use the data properly. CHEMTRONICS
does not guarantee the accuracy of the data and assumes
no liability in connection with damages incurred while
using it.
CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888
REV. H (08/13)
Chemtronics
, Electro-Wash and Konform are registered
trademarks of Chemtronics. All rights reserved.
DISTRIBUTED BY: