Handling and storage, Exposure controls/personal protection – Chemtronics Flux-Off Heavy Duty ES131 User Manual
Page 4
Flux-Off® Heavy Duty
Store in accordance with local regulations. Store in original container protected from
direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials
(see Section 10) and food and drink. Keep container tightly closed and sealed until
ready for use. Containers that have been opened must be carefully resealed and kept
upright to prevent leakage. Do not store in unlabeled containers. Use appropriate
containment to avoid environmental contamination.
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Avoid exposure - obtain special instructions before use. Do not get in eyes or on skin or
clothing. Do not ingest. Avoid breathing vapor or mist. If during normal use the
material presents a respiratory hazard, use only with adequate ventilation or wear
appropriate respirator. Keep in the original container or an approved alternative made
from a compatible material, kept tightly closed when not in use. Empty containers retain
product residue and can be hazardous. Do not reuse container.
7. Handling and storage
Handling
Storage
:
:
trans-dichloroethylene
ACGIH TLV (United States, 3/2012).
TWA: 200 ppm 8 hours.
TWA: 793 mg/m³ 8 hours.
Butane, 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxy- AIHA WEEL (United States, 10/2011).
TWA: 750 ppm 8 hours.
Propane, 2-(difluoromethoxymethyl)-1,1,1,2,3,3,
3-heptafluoro-
AIHA WEEL (United States, 10/2011).
TWA: 750 ppm 8 hours.
ethanol
ACGIH TLV (United States, 3/2012).
STEL: 1000 ppm 15 minutes.
NIOSH REL (United States, 1/2013).
TWA: 1900 mg/m³ 10 hours.
TWA: 1000 ppm 10 hours.
OSHA PEL (United States, 6/2010).
TWA: 1900 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
TWA: 1900 mg/m³ 8 hours.
TWA: 1000 ppm 8 hours.
8. Exposure controls/personal protection
Personal protection
Engineering measures
:
If user operations generate dust, fumes, gas, vapor or mist, use process enclosures,
local exhaust ventilation or other engineering controls to keep worker exposure to
airborne contaminants below any recommended or statutory limits.
Hygiene measures
:
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.
Ingredient
Exposure limits
4/10