beautypg.com

Toxicological information, Ecological information, Disposal considerations – Chemtronics Electro-Wash NXO ES1607 User Manual

Page 7

background image

Electro-Wash® NXO Cleaner Degreaser

11. Toxicological information

Mutagenicity

Conclusion/Summary

:

Not available.

Teratogenicity

Conclusion/Summary

:

Not available.

Reproductive toxicity

Conclusion/Summary

:

Not available.

12. Ecological information

Ecotoxicity

:

No known significant effects or critical hazards.

Aquatic ecotoxicity

trans-dichloroethylene

Acute LC50 220000 to 290000 µg/l
Fresh water

Daphnia - Daphnia magna

48 hours

ethanol

Acute EC50 17.921 mg/l Marine water

Algae - Ulva pertusa

96 hours

Acute EC50 2000 µg/l Fresh water

Daphnia - Daphnia magna

48 hours

Acute LC50 25500 µg/l Marine water

Crustaceans - Artemia
franciscana - Larvae

48 hours

Acute LC50 42000 µg/l Fresh water

Fish - Oncorhynchus mykiss

4 days

Chronic NOEC 4.995 mg/l Marine water

Algae - Ulva pertusa

96 hours

Chronic NOEC 0.375 ul/L Fresh water

Fish - Gambusia holbrooki -
Larvae

12 weeks

Product/ingredient name

Species

Result

Exposure

Conclusion/Summary

:

Not available.

Persistence/degradability

Conclusion/Summary

:

Not available.

The generation of waste should be avoided or minimized wherever possible. Disposal
of this product, solutions and any by-products should at all times comply with the
requirements of environmental protection and waste disposal legislation and any
regional local authority requirements. Dispose of surplus and non-recyclable products
via a licensed waste disposal contractor. Waste should not be disposed of untreated to
the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Waste packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible. This material and its container must be disposed of in a
safe way. Empty containers or liners may retain some product residues. Do not
puncture or incinerate container.

Waste disposal

13. Disposal considerations

Disposal should be in accordance with applicable regional, national and local laws and regulations.

:

Refer to Section 7: HANDLING AND STORAGE and Section 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
for additional handling information and protection of employees.

United States - RCRA Toxic hazardous waste "U" List

1,2-Dichloroethylene; Ethene, 1,2-dichloro-, (E)-

156-60-5

Listed

U079

Ingredient

CAS #

Status

Reference
number

7/11

4014

7/8/2013.