6. Accidental release measures

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Approach release from upwind. Prevent entry into sewers,
water courses, basements or confined areas. Wash spillages into an effluent treatment
plant or proceed as follows. Contain and collect spillage with non-combustible,
absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in
container for disposal according to local regulations (see Section 13). Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilled product. Note: see Section 1 for emergency contact
information and Section 13 for waste disposal.

Large spill

:

Store in accordance with local regulations. Store in a segregated and approved area.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated
area, away from incompatible materials (see Section 10) and food and drink. Eliminate
all ignition sources. Separate from oxidizing materials. Keep container tightly closed
and sealed until ready for use. Containers that have been opened must be carefully
resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Use appropriate containment to avoid environmental contamination.

Put on appropriate personal protective equipment (see Section 8). Eating, drinking and
smoking should be prohibited in areas where this material is handled, stored and
processed. Workers should wash hands and face before eating, drinking and smoking.
Remove contaminated clothing and protective equipment before entering eating areas.
Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest.
Use only with adequate ventilation. Wear appropriate respirator when ventilation is
inadequate. Do not enter storage areas and confined spaces unless adequately
ventilated. Keep in the original container or an approved alternative made from a
compatible material, kept tightly closed when not in use. Store and use away from heat,
sparks, open flame or any other ignition source. Use explosion-proof electrical
(ventilating, lighting and material handling) equipment. Use non-sparking tools. Take
precautionary measures against electrostatic discharges. To avoid fire or explosion,
dissipate static electricity during transfer by grounding and bonding containers and
equipment before transferring material. Empty containers retain product residue and
can be hazardous. Do not reuse container.

7. Handling and storage

Handling

Storage

:

:

Isopropyl alcohol

ACGIH TLV (United States, 3/2012).
STEL: 400 ppm 15 minutes.
TWA: 200 ppm 8 hours.
NIOSH REL (United States, 1/2013).
STEL: 1225 mg/m³ 15 minutes.
STEL: 500 ppm 15 minutes.
TWA: 980 mg/m³ 10 hours.
TWA: 400 ppm 10 hours.
OSHA PEL (United States, 6/2010).
TWA: 980 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.
OSHA PEL 1989 (United States, 3/1989).
STEL: 1225 mg/m³ 15 minutes.
STEL: 500 ppm 15 minutes.
TWA: 980 mg/m³ 8 hours.
TWA: 400 ppm 8 hours.

glycerol

ACGIH TLV (United States, 3/2012).
TWA: 10 mg/m³ 8 hours. Form: Mist
OSHA PEL (United States, 6/2010).
TWA: 5 mg/m³ 8 hours. Form: Respirable fraction

8. Exposure controls/personal protection

Ingredient

Exposure limits

4/11

8300