Toxicological information, Ecological information, Disposal considerations – Chemtronics CircuitWorks The Mighty Pen CW3700 User Manual
Page 6

CircuitWorks® The Mighty Pen®
11. Toxicological information
Carcinogenicity
Conclusion/Summary
:
Not available.
Mutagenicity
Conclusion/Summary
:
Not available.
Teratogenicity
Conclusion/Summary
:
Not available.
Reproductive toxicity
Conclusion/Summary
:
Not available.
Classification
tetrahydrofuran
-
-
-
A3
-
None.
Product/ingredient name
ACGIH EPA
NIOSH
NTP
IARC
OSHA
Irritation/Corrosion
Conclusion/Summary
:
Not available.
Sensitizer
Conclusion/Summary
:
Not available.
12. Ecological information
Ecotoxicity
:
No known significant effects or critical hazards.
Aquatic ecotoxicity
tetrahydrofuran
Acute LC50 2160000 to 2360000 µg/l
Fresh water
Fish - Pimephales promelas
96 hours
Chronic NOEC 367 mg/l Fresh water
Fish - Pimephales promelas -
Embryo
33 days
Product/ingredient name
Species
Result
Exposure
Conclusion/Summary
:
Not available.
Persistence/degradability
Conclusion/Summary
:
Not available.
Other adverse effects
:
No known significant effects or critical hazards.
The generation of waste should be avoided or minimized wherever possible. Disposal
of this product, solutions and any by-products should at all times comply with the
requirements of environmental protection and waste disposal legislation and any
regional local authority requirements. Dispose of surplus and non-recyclable products
via a licensed waste disposal contractor. Waste should not be disposed of untreated to
the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Waste packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible. This material and its container must be disposed of in a
safe way. Care should be taken when handling emptied containers that have not been
cleaned or rinsed out. Empty containers or liners may retain some product residues.
Vapor from product residues may create a highly flammable or explosive atmosphere
inside the container. Do not cut, weld or grind used containers unless they have been
cleaned thoroughly internally. Avoid dispersal of spilled material and runoff and contact
with soil, waterways, drains and sewers.
Waste disposal
13. Disposal considerations
:
United States - RCRA Toxic hazardous waste "U" List
Tetrahydrofuran (I); Furan, tetrahydro-(I)
109-99-9
Listed
U213
Ingredient
CAS #
Status
Reference
number
6/9
3700
5/23/2013.