First aid measures, Fire-fighting measures, Accidental release measures – Chemtronics CircuitWorks® Rubber Keypad Repair Kit CW2605 User Manual
Page 3

Circuitworks® Rubber Keypad Repair Part A
4. First aid measures
Wash out mouth with water. Do not induce vomiting unless directed to do so by medical
personnel. Never give anything by mouth to an unconscious person. Get medical
attention immediately.
Move exposed person to fresh air. If not breathing, if breathing is irregular or if
respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention
immediately.
Inhalation
Ingestion
No specific treatment. Treat symptomatically. Contact poison treatment specialist
immediately if large quantities have been ingested or inhaled.
Notes to physician
:
:
:
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. It may
be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Wash
contaminated clothing thoroughly with water before removing it, or wear gloves.
Use dry chemical, CO₂, water spray (fog) or foam.
5. Fire-fighting measures
Extinguishing media
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Combustible liquid. In a fire or if heated, a pressure increase will occur and the
container may burst, with the risk of a subsequent explosion. The vapor/gas is heavier
than air and will spread along the ground. Vapors may accumulate in low or confined
areas or travel a considerable distance to a source of ignition and flash back.
Special protective
equipment for fire-fighters
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
:
Special exposure hazards
:
Do not use water jet.
Suitable
:
Not suitable
:
Hazardous thermal
decomposition products
:
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
metal oxide/oxides
Flammability of the product
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. Do not touch or walk through spilled material. Shut off all ignition sources.
No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide
adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put
on appropriate personal protective equipment (see Section 8).
Environmental precautions
6. Accidental release measures
:
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).
Personal precautions
:
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively,
or if water-insoluble, absorb with an inert dry material and place in an appropriate waste
disposal container. Dispose of via a licensed waste disposal contractor.
Small spill
:
Methods for cleaning up
3/11