USAGE INSTRUCTIONS
Read MSDS carefully prior to use.
Mixing: Pour the liquid in Part B into the
container of Part A. Stir thoroughly for two
minutes.
Application: Clean contacts with contact
cleaner. Paint the worn carbon contacts
with the mixed conductive material using
the enclosed applicator brushes. Use the
least amount of conductive material as
possible.
Curing: At room temperature (<25
°C),
material dries tack-free in one hour.
Repaired keypads can be returned to service
in 24 hours. Ultimate properties are
achieved in 72 hours. For faster drying,
expose the material to approximately 190
°F
(90
°C) for 10 minutes. DO NOT EXCEED
212
°F (100°C).
TECHNICAL & APPLICATION
ASSISTANCE
Chemtronics provides a technical hotline to
answer your technical and application
related questions. The toll free number is:
1-800-TECH-401.
AVAILABILITY
CW2605 1 set containing:
3g / 0.36 oz. Adhesive
0.33g / 0.01 oz. Curing Agent
NOTE:
This information is believed to be accurate. It is
intended for professional end users having the skills
to evaluate and use the data properly.
CHEMTRONICS does not guarantee the accuracy
of the data and assumes no liability in connection
with damages incurred while using it.
CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888
REV. G (08/13)