beautypg.com

Toxicological information, Ecological information, Disposal considerations – Chemtronics CircuitWorks® No Clean Flux Remover Pen CW9100 User Manual

Page 7

background image

Circuitworks® No Clean Flux Remover Pen

11. Toxicological information

Mutagenicity

Conclusion/Summary

:

Not available.

Teratogenicity

Conclusion/Summary

:

Not available.

Reproductive toxicity

Conclusion/Summary

:

Not available.

acetone

-

-

-

A4

-

None.

1-methoxy-2-propanol

-

-

-

-

-

None.

benzyl alcohol

-

-

-

-

-

None.

Product/ingredient name

ACGIH EPA

NIOSH

NTP

IARC

OSHA

12. Ecological information

Ecotoxicity

:

No known significant effects or critical hazards.

Aquatic ecotoxicity

acetone

Acute EC50 20.565 mg/l Marine water

Algae - Ulva pertusa

96 hours

Acute LC50 6000000 µg/l Fresh water

Crustaceans - Gammarus pulex

48 hours

Acute LC50 10000 µg/l Fresh water

Daphnia - Daphnia magna

48 hours

Acute LC50 100 mg/l Fresh water

Fish - Pimephales promelas -
Juvenile (Fledgling, Hatchling,
Weanling)

96 hours

Chronic NOEC 4.95 mg/l Marine water

Algae - Ulva pertusa

96 hours

Chronic NOEC 0.1 ml/L Fresh water

Daphnia - Daphnia magna -
Neonate

21 days

benzyl alcohol

Acute LC50 10000 µg/l Fresh water

Fish - Lepomis macrochirus

96 hours

Product/ingredient name

Species

Result

Exposure

Conclusion/Summary

:

Not available.

Persistence/degradability

Conclusion/Summary

:

Not available.

Other adverse effects

:

No known significant effects or critical hazards.

The generation of waste should be avoided or minimized wherever possible. Disposal
of this product, solutions and any by-products should at all times comply with the
requirements of environmental protection and waste disposal legislation and any
regional local authority requirements. Dispose of surplus and non-recyclable products
via a licensed waste disposal contractor. Waste should not be disposed of untreated to
the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Waste packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible. This material and its container must be disposed of in a
safe way. Care should be taken when handling emptied containers that have not been
cleaned or rinsed out. Empty containers or liners may retain some product residues.
Vapor from product residues may create a highly flammable or explosive atmosphere
inside the container. Do not cut, weld or grind used containers unless they have been
cleaned thoroughly internally. Avoid dispersal of spilled material and runoff and contact
with soil, waterways, drains and sewers.

Waste disposal

13. Disposal considerations

Disposal should be in accordance with applicable regional, national and local laws and regulations.

:

United States - RCRA Toxic hazardous waste "U" List

Acetone (I); 2-Propanone (I)

67-64-1

Listed

U002

Ingredient

CAS #

Status

Reference
number

7/10

CW9100

5/23/2013.