8. Exposure controls/personal protection

Use a properly fitted, air-purifying or air-fed respirator complying with an approved
standard if a risk assessment indicates this is necessary. Respirator selection must be
based on known or anticipated exposure levels, the hazards of the product and the safe
working limits of the selected respirator.

Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists or
dusts. If contact is possible, the following protection should be worn, unless the
assessment indicates a higher degree of protection: chemical splash goggles.
Personal protective equipment for the body should be selected based on the task being
performed and the risks involved and should be approved by a specialist before
handling this product.
When there is a risk of ignition from static electricity, wear anti-static protective clothing.
For the greatest protection from static discharges, clothing should include anti-static
overalls, boots and gloves.

Personal protection

Eyes

Skin

Respiratory

:

:

:

Chemical-resistant, impervious gloves complying with an approved standard should be
worn at all times when handling chemical products if a risk assessment indicates this is
necessary. Considering the parameters specified by the glove manufacturer, check
during use that the gloves are still retaining their protective properties. It should be
noted that the time to breakthrough for any glove material may be different for different
glove manufacturers. In the case of mixtures, consisting of several substances, the
protection time of the gloves cannot be accurately estimated.

Hands

:

Engineering measures

:

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or
other engineering controls to keep worker exposure to airborne contaminants below any
recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.

Hygiene measures

:

Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.

Environmental exposure
controls

:

Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.

82°C (179.6°F)

Liquid. [Liquid.]

0.85

2 [Air = 1]

4.4 kPa (33 mm Hg) [room temperature]

Alcohol-like.

Yellow.

Boiling/condensation point

>1 (butyl acetate = 1)

9. Physical and chemical properties

Physical state

Relative density
Vapor pressure
Vapor density
Evaporation rate

Odor

Color

:

:
:
:
:
:
:
:

Flash point

:

Closed cup: 17°C (62.6°F) [Tagliabue.]