COMPATIBILITY

60 Minute Conductive Epoxy is generally
compatible with most materials used in printed
circuit board fabrication. As with any
adhesive/sealant, compatibility with substrate
should be determined on a non-critical area prior to
use.


USAGE INSTRUCTIONS

Read MSDS carefully prior to use.

Cleaning: For best results, clean the board prior to
application with a Chemtronics

ControlWipe

and Chemtronics

Electro-Wash

PX to remove any

surface contamination which may prevent adequate
material contact.

Mixing: Mix equal amounts (1:1) by weight or
volume of Part A and Part B. Mix thoroughly for 2-
3 minutes and apply within 1-2 hours.

Thinning: Do not attempt to thin.

Curing: Curing times and electrical conductivity
depend primarily on temperature. For fastest curing
times, maximum conductivity and adhesion, cure
the bond at 175

°F to 212°F (80 to 100°C) for 10-15

minutes. It can be room temperature cured at or
above 77

°F (25°C) for 24 hours. Maximum

conductivity and bond strength are achieved in 36
hours. Curing at temperatures below 77

°F

(25

°C) will result in a loss of conductivity and

adhesion.

Pot Life:
1-2 hours at 20-25

°C after mixing (3-5

gram mass).

AVAILABILITY

CW2460

Part A 10 g. adhesive per mixing jar

Part B 10 g. hardener per mixing jar








ENVIRONMENTAL IMPACT DATA

ODP

None

VOC

None

HCFC

None

HFC

None


Ozone depletion potential (ODP) is determined in accordance with the
Montreal Protocol and U.S. Clean Air Act of 1990.

Hydrochlorofluorocarbons (HCFCs) are regulated under the Montreal
Protocol as Class II ozone depleting substances. Volatile Organic Compound
(VOC) information is calculated on a weight basis using the VOC definition
of California Air Resources Board (CARB) Consumer Product Regulations,
South Coast Air Quality Management District (SCAQMD) Rule 102 and the
Federal definition published in 40 CFR 51.100(s). Hydrofluorocarbons
(HFCs) are not currently regulated.

TECHNICAL & APPLICATION
ASSISTANCE

Chemtronics provides a technical hotline to answer
your technical and application related questions.
The toll free number is: 1-800-TECH-401.


NOTE:

This information is believed to be accurate. It is
intended for professional end users having the skills
to evaluate and use the data properly.

CHEMTRONICS does not guarantee the accuracy
of the data and assumes no liability in connection
with damages incurred while using it.

Chemtronics

, Electro-Wash and CircuitWorks are registered trademarks

of Chemtronics. All rights reserved. ControlWipes

 is a trademark of

Chemtronics. All rights reserved.


CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888

REV. C (08/13)

DISTRIBUTED BY: