beautypg.com

Performance, Usage instructions, Technical & application assistance – Chemtronics 152a Duster ES1027 User Manual

Page 2: Availability, Environmental impact data

background image

Material

Compatibility

Buna-N

Excellent

Graphite

Excellent

HDPE

Excellent

LDPE

Excellent

Lexan

Excellent

Neoprene

Excellent

Cross-Linked PE

Excellent

Polyacrylate

Excellent

Polystyrene

Excellent

PVC

Excellent

Silicone Rubber

Excellent

Teflon

Excellent

Viton

Excellent

PERFORMANCE

Pressure PSIG / Temperature F

200 -

P 150 -

S

I 100 -

G

50 -

0

70

80

90

100

110

120

130

Temperature F

USAGE INSTRUCTIONS

For industrial use only.
Read MSDS carefully prior to use.
No special surface preparation is required prior to
using 152a Duster. Direct high pressure spray onto
the area to be cleaned to remove dust, dirt and other
contaminants. For optimum performance and pin
point control, use 152a Duster with the attached
extension tube. Do not use near ignition sources or
energized equipment. Do not spray into enclosed
areas where flammable vapors may accumulate.

TECHNICAL & APPLICATION
ASSISTANCE

Chemtronics provides a technical hotline to answer
your technical and application related questions. The
toll free number is 1-800-TECH-401, or e-mail us at

[email protected]

.

Chemtronics is also accessible on the web. Visit us at
www.chemtronics.com.


AVAILABILITY

ES1027 10 oz. Aerosol



ENVIRONMENTAL IMPACT DATA

ENVIRONMENTAL IMPACT DATA

CFC

0.0%

VOC

0.0%

HCFC

0.0%

HFC

100.0%

GWP

140

ODP

0.0


CFC, HCFC, VOC, and HFC numbers shown are the content by
weight. Ozone depletion potential (ODP) is determined in
accordance with the Montreal Protocol and U.S. Clean Air Act
of 1990. The ODP of this product is 0.0. It is the sum of the
ODP of the substances that may contribute to the depletion of
stratospheric ozone, based upon the weight of each substance in
the product’s formulation

.

Global warming potential (GWP) is

calculated based on a 100 year time horizon. Carbon dioxide has
a GWP of 1.

NOTE:

This information is believed to be accurate. It is intended
for professional end users having the skills to evaluate and
use the data properly. CHEMTRONICS does not
guarantee the accuracy of the data and assumes no liability
in connection with damages incurred while using it.


Chemtronics

 is a registered trademark of Chemtronics. All rights reserved.

All rights reserved. All other trademarks herein are trademarks or registered
trademarks of their respective owners.

CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888

REV. A 08/13