Performance, Usage instructions, Technical & application assistance – Chemtronics 152a Blast EU Label ES1029 User Manual
Page 2: Availability, Environmental impact data

Material
Compatibility
Buna-N
Excellent
Graphite
Excellent
HDPE
Excellent
LDPE
Excellent
Lexan
Excellent
Neoprene
Excellent
Cross-Linked PE
Excellent
Polyacrylate
Excellent
Polystyrene
Excellent
PVC
Excellent
Silicone Rubber
Excellent
Teflon
Excellent
Viton
Excellent
PERFORMANCE
Pressure PSIG / Temperature °C
200 -
P
150 -
S
I
100 -
G
50 -
0
21
27
32
38
43
49
54
Temperature °C
USAGE INSTRUCTIONS
For industrial use only.
Read MSDS carefully prior to use.
No special surface preparation is required prior to
using 152a Blast™. Direct high pressure spray onto
the area to be cleaned to remove dust, dirt and other
contaminant. For optimum performance and pin point
control, use with the attached extension tube. Do not
use near ignition sources or energized equipment.
Do not spray into enclosed areas where flammable
vapors may accumulate.
TECHNICAL & APPLICATION
ASSISTANCE
Chemtronics provides a technical hotline to answer
your technical and application related questions. The
toll free number is 1-800-TECH-401, or e-mail us at
Chemtronics is also accessible on the web. Visit us at
www.chemtronics.com.
AVAILABILITY
ES1029E 400 ml Aerosol
ENVIRONMENTAL IMPACT DATA
ENVIRONMENTAL IMPACT DATA
CFC
0.0%
VOC
0.0%
HCFC
0.0%
HFC
100.0%
GWP
140
ODP
0.0
CFC, HCFC, VOC, and HFC numbers shown are the content by
weight. Ozone depletion potential (ODP) is determined in
accordance with the Montreal Protocol and U.S. Clean Air Act
of 1990. The ODP of this product is 0.0. It is the sum of the
ODP of the substances that may contribute to the depletion of
stratospheric ozone, based upon the weight of each substance in
the product’s formulation.
Global warming potential (GWP) is
calculated based on a 100 year time horizon. Carbon dioxide has
a GWP of 1.
NOTE:
This information is believed to be accurate. It is intended
for professional end users having the skills to evaluate and
use the data properly. CHEMTRONICS does not
guarantee the accuracy of the data and assumes no liability
in connection with damages incurred while using it.
Chemtronics
is a registered trademark of Chemtronics. All rights reserved.
152a Blast is a trademark of Chemtronics. All rights reserved. All other
trademarks herein are trademarks or registered trademarks of their respective
owners.
CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888
REV A. 08/13
DISTRIBUTED BY: