beautypg.com

Maximum ratings, Operating range, Dc electrical characteristics – Cypress STK11C68 User Manual

Page 5: Data retention and endurance, Stk11c68

background image

STK11C68

Document Number: 001-50638 Rev. **

Page 5 of 16

Maximum Ratings

Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.

Storage Temperature ................................. –65

°C to +150°C

Temperature under bias.............................. –55

°C to +125°C

Supply Voltage on V

CC

Relative to GND ..........–0.5V to 7.0V

Voltage on Input Relative to Vss............ –0.6V to V

CC

+ 0.5V

Voltage on DQ

0-7

...................................–0.5V to Vcc + 0.5V

Power Dissipation ......................................................... 1.0W

DC Output Current (1 output at a time, 1s duration).... 15 mA

Operating Range

Range

Ambient

Temperature

V

CC

Commercial

0

°C to +70°C

4.5V to 5.5V

Industrial

-40

°C to +85°C

4.5V to 5.5V

DC Electrical Characteristics

Over the operating range (V

CC

= 4.5V to 5.5V)

Parameter

Description

Test Conditions

Min

Max

Unit

I

CC1

Average V

CC

Current

t

RC

= 25 ns

t

RC

= 35 ns

t

RC

= 45 ns

Dependent on output loading and cycle rate.
Values obtained without output loads.
I

OUT

= 0 mA.

Commercial

90
75
65

mA
mA
mA

Industrial

90
75
65

mA
mA
mA

I

CC2

Average V

CC

Current

during STORE

All Inputs Do Not Care, V

CC

= Max

Average current for duration t

STORE

3

mA

I

CC3

Average V

CC

Current at

t

RC

= 200 ns, 5V, 25°C

Typical

WE > (V

CC

– 0.2V). All other inputs cycling.

Dependent on output loading and cycle rate. Values obtained
without output loads.

10

mA

I

SB1

[2]

V

CC

Standby Current

(Standby, Cycling TTL
Input Levels)

t

RC

= 25 ns, CE > V

IH

t

RC

= 35 ns, CE > V

IH

t

RC

= 45 ns, CE > V

IH

Commercial

27
23
20

mA
mA
mA

Industrial

28
24
21

mA
mA
mA

I

SB2

[2]

V

CC

Standby Current

CE > (V

CC

– 0.2V). All others V

IN

< 0.2V or >

(V

CC

– 0.2V). Standby current level after

nonvolatile cycle is complete.
Inputs are static. f = 0 MHz.

Commercial

750

μA

Industrial

1500

μA

I

IX

Input Leakage Current V

CC

= Max, V

SS

< V

IN

< V

CC

-1

+1

μA

I

OZ

Off State Output
Leakage Current

V

CC

= Max, V

SS

< V

IN

< V

CC

, CE or OE > V

IH

or WE < V

IL

-5

+5

μA

V

IH

Input HIGH Voltage

2.2

V

CC

+

0.5

V

V

IL

Input LOW Voltage

V

SS

– 0.5

0.8

V

V

OH

Output HIGH Voltage

I

OUT

= –4 mA

2.4

V

V

OL

Output LOW Voltage

I

OUT

= 8 mA

0.4

V

Data Retention and Endurance

Parameter

Description

Min

Unit

DATA

R

Data Retention

100

Years

NV

C

Nonvolatile STORE Operations

1,000

K

Note

2. CE > V

IH

does not produce standby current levels until any nonvolatile cycle in progress has timed out.

[+] Feedback