Humidity too high when unit is not running, Humidity too high when unit is running and cooling, Other miscellaneous problems – Wine Guardian Ducted Wine Cellar Cooling System (D0200) - Manual User Manual
Page 54: Unit operates but the power switch light is not on, Unit is leaking water

54
Humidity too high when unit is not running
Possible Cause Solution
Unit needs to run to dehumidify Run unit. Seal openings around doors (gasket
and sweep)
Humidity too high when unit is running and cooling
Possible Cause Solution
Too much moisture in cellar Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions.
Add dehumidifier to surrounding space
Other Miscellaneous Problems
Unit operates but the power switch light is not ON
Possible Cause
Solution
Bulb is burned out
Replace bulb
Unit is leaking water
Possible Cause
Solution
Piping from unit to drain is trapped Re-pipe to remove external traps
Trap plugged Clean trap
Condensate pan plugged
Remove blockage and clean
Unit not level
Level with shims
Unit is running properly, but the sound of the unit is objectionable
Possible Cause Solution
Noise is from airflow
Noise if from unit
Redirect airflow
Add baffles
Add insulated ductwork
Add sound baffle between unit and occupied