beautypg.com

Wine Guardian Ducted Wine Cellar Cooling System (D0200) - Manual User Manual

Page 19

background image

Model Number

D025

D050

volt/phase/hz

115/1/60

115/1/60

208/1/60

230/1/60

208/1/60

230/1/60

HP

0.33

0.50

1

1

2.5

2.5

Total/Sensible

Total/Sensible

Total/Sensible

Total/Sensible

Total/Sensible

Total/Sensible

BTUH

4520/3050

6920/4920

10700/7120

10830/7500

17570/12430

17680/12790

BTUH

4300/2915

6570/4740

9900/6800

10250/7160

16580/11650

16720/12000

BTUH

3760/2715

6320/4510

9420/6610

9600/6850

15350/11100

15680/11780

BTUH

3540/2580

5860/4230

8600/6120

8760/6210

14000/10580

15000/10870

BTUH

3260/2400

4865/3820

N/A

N/A

N/A

N/A

BTUH

3000/2260

4585/3590

N/A

N/A

N/A

N/A

Digital electronic

Digital electronic

1F / 10%

1F / 10%

Watts

75

100

175

195

160

180

CFM

245

390

435

485

760

810

CFM

200 @0.10" wc

320 @0.20" wc

370 @0.20" wc 440 @0.20" wc

710 @0.35" wc

745 @0.35" wc

Watts

75

100

175

195

160

180

CFM

245

390

435

485

760

810

CFM

200 @0.10" wc

320 @0.20" wc

370 @0.20" wc 440 @0.20" wc

700 @0.35" wc

725 @0.35" wc

GMP

0.30

0.60

PSI

0.40

0.40

Inches

0.50

0.63

Heat (Option)

Electric

Electric

Electric

Electric

Electric

Electric

Watt/BTUH

1000/3400

1000/3400

1635/5582

2000/6800

1635/5582

2000/6800

lbs./hr

lbs./hr

lbs./hr

Amps

7.1

11.3

9.8

8.8

15.6

14.1

Amps

9.4

9.6

8.8

9.5

8.8

9.5

Amps

11.6/8.6

11.8/13.7

10.7/11.8

11.7/10.6

10.7/19.1

11.7/17.2

Amps

0.4

0.4

0.2

0.2

0.2

0.2

Amps

0.2

0

N/A

N/A

N/A

N/A

Amps

0.4

0.4

0.4

0.4

0.4

0.4

lbs.

80

125

Width

33

33

Depth

14

22

Height

14

14

inches

.50"

.50"

ETL

UL 1995 / CSA C22.2UL 1995 / CSA C22.2

2. Wine Guardian reserves the right to make changes to this document without prior notice at its sole discretion.
3. All rating at sea level.

800-825-3268 | 315-452-7400 | www.wineguardian.com | [email protected]

Wine Guardian

® is a registered trademark of Air Innovations

Current Draw - Heating mode

Minimum Circuit amps (heat / no heat)

Condensate Drain connection (ID)

Optional Humidifier

Construction

Dimensions (inches)

Current Draw - Cooling mode

Type

4. D200 air flow based on 0.35 inches Wine Guardian external static pressure using 50' of flexible ductwork, grills and collars. Rev. 10-2014

Power Requirements

Optional Low Ambient

Optional High Ambient

@60 Deg F condenser inlet air

Finish

@80 Deg F condenser inlet air

@90 Deg F condenser inlet air

@110 Deg F condenser inlet air

@120 Deg F condenser inlet air

Weight

Pipe connection size (in/out) O.D.

Type

Capacity - water temp of 90 Deg F

Capacity - water temp of 100 Deg F

7000 Performance Drive | North Syracuse, New York 13212 USA

1. Net cooling capacity at entering temperature and humidity conditions of 57 Deg F and 55% RH at rated airflow. Reduce capacity by 3% for each 10% reduction in evaporator airflow.

0.50

@70 Deg F condenser inlet air

Fan Motor Size

Rated Air Flow (free blow)

Type

Evaporator Section

0.97

1.11

Electrical Requirements

Fan Motor Size

Rated Air Flow (free blow)

Rated Air Flow @ pressure loss

Capacity - water temp of 60 Deg F

2.50

0.08

1.20

UL 1995 / CSA C22.2

UL 1995 / CSA C22.2

Aluminum

Black - textured epoxy powder coat

130

200

33

22

D088

D200

Removable drip pad with integral fan

0.42

Water-cooled Condenser Section (option)

.50"

.50"

0.63

Rated Air Flow @ pressure loss

Digital electronic

Performance

Controls

Air-cooled Condenser Section

14

50

Cabinet

22

18

1F / 10%

Humidifier (Option)

1.20

Nominal Compressor

Net Cooling Capacity*

Capacity

Water usage at 40 Deg F rise

Pressure drop

Digital electronic

1F / 10%

Temperature Accuracy/RH% Accuracy