Wine Guardian Ducted Wine Cellar Cooling System (D0200) - Manual User Manual
Page 37

37
Deg F or Deg C
Setting 1
Press the “Down” arrow to change
temperature from Deg F to Deg C.
Press the “Up” arrow to change temperature
from Deg C to Deg F.
Low temperature
alarm setpoint
Setting 2
Press “Mode” button to advance to Setting 2.
Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 50 Deg. F.
High temperature
alarm setpoint
Setting 3
Press “Mode” button to advance to Setting 3.
Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 65 Deg F.
Low humidity alarm
set point
Setting 4
Press “Mode” button to advance to Setting 4.
Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is 5%.
High humidity alarm
setpoint
Setting 5
Press “Mode” button to advance to Setting 5.
Press the up or down arrow buttons to adjust
to the desired setpoint. Factory default is
95%.
Add or remove
humidifier
Setting 6
Press “Mode” button to advance to Setting 6.
Press the “Up” or “Down” arrow buttons to
adjust to the desired setpoint. Factory default
is zero (0).
Zero (0) = No humidifier
One (1) = Integral Wine Guardian mounted
humidifier
Two (2) = Stand-alone remote mounted
humidifier
Fan AUTO or ON
Setting 7
Press “Mode” button to advance to Setting 7.
Press the “Up” or “Down” arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).
Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating
One (1) = Fan On – fan remains on
continuously