beautypg.com

6 - c, 7 - e, 8 - o – Vintage Cellars Transtherm Double Ermitage Solid Door Black User Manual

Page 14: Iv. setting the lighting mode (all models), Ommissioning, Your, Wine, Cabinet, Veryday, Maintenance

background image

14

GB

IV. Setting the lighting mode (all models)

1

Press the

key approximately 5 seconds.

The indicator of the active mode will flash

2

Press the

or

keys to select the desired mode.

3

Press the

key to confirm

There are 3 setting options for lighting:

Permanent lighting (mood lighting for a cabinet fitted with a glass

door, for example).

Lighting which comes on when the door opens (it is switched off

when the cabinet door is closed).

Lighting disabled

Precaution : bright light, never look directly at the LED beam.

6 - c

ommissioning

your

Wine

cABinet

Maintenance operations to be carried out approximately once a year

Unplug and unload the appliance.

Regularly vacuum the condenser at the back of the appliance.

Clean the inside of the compartments with water and a gentle cleaning product.

Rinse thoroughly.

Check that the seals are in good condition.

Your Transtherm cabinet is a tried and tested appliance.

Regular monitoring of your

cabinet and reporting any faults

to your retailer will ensur

e

that your appliance provides

you with many years of faithful

service.

7 - e

veryDAy

mAintenAnce

Possible incidents

Causes

Corrective actions

The

pictogram is displaying

The temperature
has not returned to
within the ±4°C / 39°F
threshold

Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
Transtherm retailer.

The

pictogram is still displaying

even though I have taken the corrective
actions above

Operating fault

Unplug the cabinet and contact your Transtherm retailer.

The

pictogram is displaying

Open door alarm

Make sure that the door is correctly closed.

The

pictogram is flashing

The level of relative
humidity has been <
50 % for over 72 hrs

• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram was
displayed
After a few hours, the pictogram will disappear.

The

pictogram is displaying

Temperature sensor
fault alarm

Contact your Transtherm retailer.

If your appliance does not seem to be working correctly,
contact your Transtherm retailer.

The use of glass doors can alter your wine cabinet’s performance
in some extreme temperature conditions.

8 - o

perAting

FAults