Reference Designation

Troubleshooting

SYMPTOM CAUSE

SOLUTION

Motor piston

Piston stalled

Reset piston, by hand

Air has not been

Bleed air from unit,

bled from unit

by bleed button

Maximum flow

1. Reduce flow,

exceeded.

restart unit

2. Unscrew the bell.

Take off the piston and
check piston valves
seals to ensure correct
position

Motor piston

Return unit to your

is damaged

service center for repair

Injection

Water flowing back Contaminated, worn,

Clean or replace it

into concentrate

or missing check

container valve

parts

No suction of

The piston motor

See Motor piston section

concentrate has

stopped

Air leak (inlet) in the Check the tightness bet-

suction

tube

ween nut and suction hose

Blocked suction

Clean or replace it

tube or clogged

strainer

Missing or worn

Clean or replace it

suction check valve seal

Missing or worn

Clean or replace it

plunger seal

Worn injection stem

Replace it

DOSATRON does
not start or stops

REF.

Serial #

REF. : .................................................................... Serial #:............................................................

EXAMPLE

D3

T

RE/GL

2

IE

BP

V

AF

P

II

Type of DOSATRON

Temperature

RE : adjustable
GL : Green Line (fertigation) [Green]

Dosage ( % or ratio)

IE : External Injection

BP : integrated by-pass

V : Viscous Products
( > 400 cPs)

Dosing Seals:
AF = PH 7-14
VF = PH 1-7
K = strong acids (>15%)

Color : - = Blue [PP]

P =

White [PVDF]

R =

Red [PP]

V =

Green [PP]

J =

Yellow [PP]

O = Orange [PP]

Other extensions
(consult us)