NO !

©

DOSATRON INTERNATIONAL / 47

EN

©

DOSATRON INTERNATIONAL / 46

IMPORTANT ! - Do not put the suction tube strainer on the bottom of the
stock solution container. The strainer must be suspended at least 10 cm
[4”] above the bottom of the tank to avoid sucking up the insoluble par-
ticles that may damage the injection assembly (Fig.2).
- Do not put the strainer on the ground.

Under no circumstance should the solution level be above the water
inlet of the DOSATRON (to avoid siphoning situations) (

Fig. 3)

.

ASSEMBLING THE DOSATRON (cont...)

Fig. 2

WHAT YOU SHOULD DO

WHAT YOU MUST NOT DO

INSTALLATION HINTS

EXCESSIVE FLOW (as an indication)
If your DOSATRON clicks more than 46 times, that is 23 cycles in 15
seconds*, you are close to the superior flow limit. If you need more flow, you
must install a DOSATRON with a superior capacity of flow.

*D3RE25 = 30 times, 15 cycles

The DOSATRON can be connected to
the main water line directly (Fig. 4) ;
on a by-pass (Fig. 5), recommended.
If your flow rate is above the ope-
rating limits of the DOSATRON, see
EXCESSIVE FLOW.

To prolong the working life of the
DOSATRON it is advisable to install
a filter (ex.: 300 mesh - 60 microns
depending on your water quality)
upstream.
This is imperative if the water contains
impurities or particles, especially if the
water comes from a well.

A filter is recommended and requi-
red for the warranty to be valid.

Installing the DOSATRON on a bypass
enables clean water to be supplied
without operating the DOSATRON
and the DOSATRON to be easily dis-
mantled.

When connecting an

installation to the public water

supply, you must respect the

rules and regulations in force

in the country.

Fig. 4

Check

valve

Valve

Valve

Filter

Filter

Fig. 5

Fig. 3