DIAGRAM F
DIAGRAM G
NOTE: For easy one person installations, remove (9) screws from rear and bottom of vent cabinet. Slide venter assembly out of
SS2 cabinet and set aside being careful not to damage housing. After SS2 cabinet is secured to the outside wall, and the
vibration isolation mount is installed to the inside wall, replace venter assembly and (9) screws, (See Diagram D).
7. Apply two beads of exterior rated caulk approximately 3/8" in width at the seam of the outside casing of the SS2 Vent Cabinet
and on the inner flange of the Vent Hood Termination, (See Diagram E).
9. After the SS2 is completely installed, apply a
bead of exterior rated caulk between the Vent
Hood Termination mounting flange and the
exterior of the building, (See Diagram G).
INSTALLATION OF WALL SUPPORT BRACKET
1. To prevent damage to the SS2, temporarily support the bottom of the SS2 cabinet (prop on ladder top) while assembling the
wall support bracket. Assemble the wall support bracket as shown, (See Diagram H, Page 8).
2. Connect mounting bracket to SS2 using (4) #8 x 3/8” sheet metal screws. Line up holes on bottom of SS2 with mounting bracket
to ensure proper placement, (See Diagram H, Page 8).
3. Adjust the wall support bracket so that a slight pitch is maintained for moisture drainage and vibration isolation. Use the
prepunched holes on the wall bracket as a template to mark holes to be drilled into the side wall for mounting screws,
(See Diagram H, Page 8).
8. Slide the SS2 vent cabinet through the wall with drip
flange facing down towards ground, (See Diagram F).
Mount Vent Hood to exterior using (6) #10 x 1 1/4”
wood screws provided, (See Diagram F). If installing
in masonry wall drill 1/4” holes and use wall anchors
provided.